Adjusting the Tools
6-13
6
Tr
ou
bleshoo
ting
Light Pointer Adjustment
The register marks cannot be read if the light pointer position is displaced.
First, mount a pen in Unit A.
1
Display the fifth page of the local menu.
• Press
several
times.
2
Press
and
select
TOOL ADJUST.
3
Press
several times to display
the second page of the menu.
4
Press
and
select
[LIGHT POINTER].
5
Press
to start drawing the test pattern.
• Turn on and move the light pointer.
6
Move the light pointer to the center of the
cross pattern.
• Adjust the light pointer position if it is not aligned with the
center of the pattern drawn by the pen.
Moving the light pointer in the X-axis direction
Move up
: Press
(-3 to +3 mm)
Move down
: Press
(-3 to +3 mm)
Moving the light pointer in the Y-axis direction
Move right
: Press
(-3 to +3 mm)
Move left
: Press
(-3 to +3 mm)
7
Press
to save the adjusted values.
• Press
if you do not want to save the settings.
[ LOCA L ]
5 / 5
RESERVE
- - - >
RESERVE
- - - >
TOOL AD J US T - - - >
< TOOL AD J UST > 1 / 2
B CUT T ER AD J UST >
C ROL L ER AD J UST >
C I RC L E
θ
COR
>
< TOOL AD J UST > 2 / 2
L I GHT PO I NTER
>
< PO I NT ER OFS > 1 / 1
PO I NTX
+ 0 . 0mm>
PO I NTY
+ 0 . 0mm>
T ES T PA T T ERN
- >
10
m
m
10 mm