— 1.22 —
MATCHING THE FUNCTIONS OF THE DEVICE TO
THE SPECIFICATIONS OF THE COMPUTER
The following explains how to set the functions required to connect the device to your personal
computer.
Setting communication conditions [INTERFACE]
Communication conditions for the communication between the device and the computer to which
the device is connected by way of RS232C.
Set values
Baud rate:
1200, 2400, 4800, 9600, 19200 (bps)
Data bit:
7, 8 (bit)
Parity:
NO PARITY, EVEN, ODD
Stop bit:
1, 2, (bit)
Handshake:
Hardware, X code, E/A, software
1
Press the
PAGE
+
key several times
until the LCD indicates page 3 of the
LOCAL MENU.
2
Select the [INTERFACE] from the
menu.
3
Set the [BAUD RATE] to a desired
value.
The value marked with an asterisk (*) is
the current set value.
1200, 2400, 4800, 9600, 19200 (bps)
4
Set the [DATA BITS] to one of the fol-
lowing.
7, 8 (bit)
[ LOCAL ]
1 / 4
TOOL SELECT
———>
CONDITION
———>
TEST CUT
———>
[ LOCAL ]
3 / 4
INTERFACE
———>
MODE SET
———>
SELF TEST
———>
< INTERFACE >
1 / 2
RESERVE
BAUD RATE
∗
9600 >
DATA BITS
∗
8 >
< INTERFACE >
1 / 2
RESERVE
BAUD RATE
19200 >
DATA BITS
∗
8 >
F1
+
PAGE
+
F3
+
F2
+
Summary of Contents for CF2 Series
Page 48: ...1 32...
Page 120: ...3 24...
Page 138: ...4 18...
Page 176: ...A 12 C OUTPUT SAMPLES Cutting quality 1 Cutting quality 2...
Page 177: ...A 13 ASCII dump list Sample coated...
Page 178: ...A 14 Sample E corrugated Sample B corrugated...
Page 179: ...A 15 Circle cutting R 3 5 10 20 50 100 Parameter dump list R 3 R 5 R 10 R 20 R 50 R 100...
Page 185: ......
Page 186: ...D201402 1 30 16062008 MIMAKI ENGINEERING CO LTD 2008 EM FW 2 50...