— 3.19 —
TROUBLES FOR WHICH ERROR MESSAGES ARE
GIVEN ON THE LCD
If something is wrong with the device, a corresponding error message is given on the LCD.
Causes of and corrective measures against such errors are described below.
Errors that can be corrected by users
The table below gives the errors that can be corrected by users.
Error message
Cause
Corrective measure
ERROR 10 COMMAND
ERROR 11 PARAMETER
ERROR 12 DEVICE
ERROR 13 POLYGON
ERROR 20 I/O
ERROR 27 BUFFER OVER
ERROR 30 OPERATION
Communication conditions on
the device are different from
those on the computer.
Polygon buffer has overflown.
Communication conditions on
the device are different from
those on the computer.
Power to the computer and that
to the device are turned on in the
wrong order.
An abnormal condition has arisen
in the serial interface.
Improper key operation is carried
out such as a change in the
communication conditions while
cutting or other performance of
the device is interrupted.
The effective area is smaller than
A3 and ASCII damp is executed.
The origin is set to a position
where the effective area of A3
size is not ensured, and ASCII
damp is executed.
Adjust the communication
conditions on the device to those
on the computer. See page 1.22.
Divide first the polygon data,
then transmit the divided polygon
data.
Adjust the communication
conditions on the device to those
on the computer. See page 1.22.
Turn on the power to the
computer first, then turn on the
power to the device.
Adjust the communication
conditions on the device to those
on the computer. See page 1.22.
Do not conduct any improper key
operation.
Set the effective area to A3 size
(297 x 420 mm) or more. Then,
execute ASCII damp.
Summary of Contents for CF-0907
Page 16: ......
Page 48: ......
Page 68: ......
Page 84: ......
Page 96: ......
Page 100: ...2 52...
Page 122: ......
Page 140: ......
Page 158: ...A 10...
Page 159: ...A 11 C OUTPUT SAMPLES Cutting quality 1 Cutting quality 2...
Page 160: ...A 12 ASCII dump list Sample coated...
Page 161: ...A 13 Sample E corrugated Sample B corrugated...
Page 162: ...A 14 Circle cutting R 3 5 10 20 50 100 Parameter dump list R 3 R 5 R 10 R 20 R 50 R 100...
Page 168: ...A 20...
Page 169: ......
Page 170: ...D200962 1 30 12032004 MIMAKI ENGINEERING CO LTD 2004...