2-9
2
2
2
5
6
Chapter 2 Basic Operation
Printing an image from
source data
Starting the printing operation
1
Set the media. (
• When you set the FAN MODE setting (
12) to “MANUAL”, press [SEL] and [FUNC1]
(VACUUM) depending on the use and vacuum
the media.
2
Press the
(REMOTE) in local.
• The machine goes in the remote mode and data
from the computer can be received.
• The table height (including the vacuum table and
the table spacer) is displayed.
3
Transmit data to be drawn from the
computer.
• Printing conditions are displayed.
• As for the data transmission method, see the
instruction manual of the output software.
4
Start printing.
• The printing origin is not changed after completion
of the printing.
5
Taking out the media after completion of
printing.
(1)
When you made vacuum "ON", Press the
[FUNC1] (VACUUM)
to turn the adsorption
"OFF".
(Only for UJF-3042MkII EX/UJF-3042MkII
EX e, UJF-6042MkII/UJF-6042MkII e or
when using an absorption table.)
(2)
Remove the media.
Interruption of printing
To interrupt printing, stop the printing operation and erase
the received data from the machine.
1
Press
(LOCAL) while printing.
• Printing operation stops.
• When data is transmitted from the computer, the
computer stops transmission of data.
2
Press the
key onece.
• "DATA CLEAR" appears on the lower line of the
display.
3
Press
(DATACLEAR).
4
Press the
key.
• Received data is erased and the machine returns
to the local mode. The tabel moves to the
evacuation position.
• If the temperature of the head has not reached the
predetermined value, a message is displayed.
Printing is not allowed in such cases. When the
display is disappeared, printing can be started.
• Data transmission is allowed even if errors are
displayed. Printing is started after the display is
disappeared.
• Use LT mode when you need more
flexibility.
• When LT mode is enabled, UV light
intensity is adjusted. Please check the
printing status.
PRE
POST
REMOTE
0 0mm
0 0mm 40
°
/
50
°
600x900 VD
12p / Uni / R / MP / LT 151.5mm
The length of media printed
Resolution
600 /900 /1200 DPI
Number of passes
Scan direction
Uni:Unidirectional
Height of the current table
LT mode setting
LT : LT mode active
MAPS information
MP: MAPS function active
Nozzle recovery information
R : Performing nozzle recovery
• When you use the vacuum function of
the vacuum table to draw, turn "OFF" the
vacuum when printing has been
completed.
• During printing, media may be heated by the LED
UV and raised, causing printing to be interrupted.
In this case, set new media and restart printing.
• To restart printing, press the [FUNC3]
(REMOTE).
Summary of Contents for 3042 MkII EX
Page 1: ...MIMAKI ENGINEERING CO LTD https mimaki com D203043 42 Original instructions ...
Page 16: ...Position of the warning label xv ...
Page 36: ...Chapter 1 Before Use 1 20 ...
Page 79: ...4 3 1 2 2 4 5 6 Chapter 4 Maintenance ...
Page 104: ...Chapter 4 Maintenance 4 28 ...
Page 116: ...5 12 Chapter 5 Troubleshooting ...
Page 122: ...Chapter6 Appendix 6 6 ...
Page 124: ...Chapter6 Appendix 6 8 ...