Environment
Make sure that the operating environment remains safe for SEIT 1500.
WARNING
Personal Injury or Damage Risk
An AMR can be unsafe if operated under environmental conditions other than those specified in
this manual.
Environmental Hazards
–
these are areas where it is unsafe for SEIT 1500 to operate. For
example, steep ramps (greater than 5.0 degrees).
Provide physical barriers that SEIT 1500 can detect accurately with its scanning laser so that it
does not attempt to drive near the hazard. Be aware that in addition to being easily detectable,
a barrier must be strong enough to resist a fully-loaded AMR traveling at speed.
Public Access
The AMR is designed to operate indoor industrial environments. You must deploy it only in applications
where you anticipate and mitigate potential risks to personnel and equipment.
Milvus does not intend SEIT 1500 for use in uncontrolled areas without risk analysis. For example, in
areas open to general public access. Use of SEIT 1500 in such areas requires deployment of additional
safety measures. For support, please contact Milvus Robotics.
Side Clearances
SEIT 1500 is designed to operate in environments that contain doors, passageways, or other constrained
areas that are wide enough for it to traverse. However, you must maintain adequate free space on both
sides of the AMR so that it cannot trap a person against a wall or other fixed object.
An AMR must often maneuver close to machinery, conveyors, or other fixed objects. In such cases,
operating standards usually allow an exception to side clearance requirements.
SEIT 1500 generally travels in a forward direction. It only reverses when leaving its docking station. To
change direction, SEIT 1500 rotates on its center of rotation.