34
Pellerin Milnor Corporation
External Fault Error
— This message is triggered by a device external to the MilTouch™ ma-
chine. This error usually originates with the chemical supply system.
Emergency Stop Error
— The emergency stop switch (locking push button) is locked. The
controls are disabled and the machine remains idle until the switch is unlocked. To unlock the
emergency stop switch, turn the switch clockwise.
Too Many Recycles
— Due to an unbalanced load, the machine has performed the maximum
of five extract cycles. The controller will skip to the next step in the formula. If the current (im-
balanced) extract step is the final step in the formula, the formula will end.
Control on Clean Side
— This message indicates the controls on the clean (discharge) side
are enabled on barrier machines.
Loadcell Comm Failure
— This error can occur on machines with the optional weighing sys-
tem (load cells). The controller issues this error when it cannot receive data, or receives an unex-
pected data stream from the load cell controller.
Level Too Low
— After the machine fills to the configured minimum (low) water level, the
controller turns off all outputs and signals this error if the water level drops below half of the min-
imum water level and remains below half of the minimum water level for 30 continuous seconds.
4.2.2
Error Correction
BNCLJT05.C01 0000304574 E.3 B.14 A.9 9/11/20 3:52 PM Released
Touch
(in the error code dialog box,
Figure 25: Sample Error Code Dialog Box, page 30
to view the
Error Causes/Solutions
display (shown in the following figure).
The
Error Causes/Solutions
display gives a list of possible causes for the error. Touch one of
the error causes in the list for an explanation of how to correct it.