Chapter 3. Routine Maintenance
PELLERIN MILNOR CORPORATION
a formula or operate the machine manually. It is not necessary to do the test when the
machine operates.
3. Operate an emergency stop mechanism (examples - button, kick plate, pull cord). If the
mechanism operates correctly, the operator alarm comes on. Did this occur?
Yes
—Release the emergency stop mechanism if necessary. For example, if this is an
emergency stop button, turn the button clockwise to unlock it. Push the start button
(
1
). Do the test on a different emergency stop mechanism. Continue until you do the
test on all emergency stop mechanisms on the machine.
No
—An electrical component is defective. Shut down the machine. Do not let the
machine operate until you correct the problem.
3.1.6.
Maintenance Components—Large Extractors
[Document BIWUUM03]
Figure 20: Grease Ports for Grease-only Bearing Assembly
Grease Plate 01-10025X, 01-10025Y, or 01-10025Z
Legend
.
1.
Seal grease port
2.
Rear bearing grease port
3.
Front bearing grease port
4.
Grease plate part number.
Make sure you use the
grease instructions for the
plate on your machine:
01-10025X, 01-10025Y,
or 01-10025Z.