C
HAPTER
6 - MAINTENANCE
43
Way Lube Maintenance
•
Ensure the way lube reservoir level is maintained (if equipped). (Use Mobil Vactra
No. 02, Amoco Waytec No 68, Sunoco Sunwaylube No1180, or equivalent oil,
more details found in mechanical manual).
•
Clean the intake filter screen annually.
•
Never re-use old waylube.
Adjustment
•
Never reduce the ON time or increase the OFF time without first consulting the
factory.
On / Off Timer Settings
Model / Series
On Time (Seconds)
Off Time (Minutes)
BR, VM, HM20, MM18, TT
5
60
HM35
7
45
MB, VK, RH, RW
8
28
ML, SL
7
30
There are two types of oiler timers in use as shown below.
CESD Type, MA-219
•
Set the built-in timer controls for
Seconds ON, and Minutes OFF
operation per the table above.
CEN01 Type, MA-458
•
Set the CNC parameters for
Seconds ON, and Minutes OFF
operation per the table above.
Fill with clean
oil as specified
Adjustment controls
Fill with clean
oil as specified