PL-550
IQ Radar 160/160 Ex
Page 29
In
s
ta
lla
tio
n
Mounting: Location/Beam Angle
Due to the polarization effect of
the microwave signal related to
the wall of the vessel, we
recommend locating the IQ160
a minimum of 30 cm (1’) away
from the side wall for every 3 m
(10’) of vessel height.
Antenna Beam Angle
Rod 20
o
4” Horn 28
o
6” Horn 20
o
8” Horn 12
o
Polarization Effect
Mounting the unit too close to a wall may cause echoes to disappear at
specific levels due to wave cancellation. A strong false reflection from an
internal tank obstruction can be reduced or eliminated by rotating the unit to
reduce the polarization effect.
False Reflections
Flat obstructions, and struts that are perpendicular to the emission cone,
cause large false reflections. They reflect the radar signal with high amplitude.
Round profile interfering surfaces diffuse reflections of the radar signals and
cause false reflections with low amplitude.
Beam
Angle
Keep the emission cone
free of obstructions.
Summary of Contents for IQ Radar 160
Page 1: ...33455500 Rev 3 1 IQ RADAR 160 Instruction Manual PL 550 January 2001 Q RADAR I60 ...
Page 10: ...Page 10 IQ Radar 160 160 Ex PL 550 Specifications ...
Page 32: ...Page 32 IQ Radar 160 160 Ex PL 550 Installation ...
Page 35: ...PL 550 IQ Radar 160 160 Ex Page 35 Start Up Display Aiming the Hand Programmer ...
Page 40: ...Page 40 IQ Radar 160 160 Ex PL 550 Start Up ...
Page 52: ...Page 52 IQ Radar 160 160 Ex PL 550 Operation ...
Page 62: ...Page 62 IQ Radar 160 160 Ex PL 550 Parameter Descriptions ...
Page 66: ...Page 66 IQ Radar 160 160 Ex PL 550 Appendix I ...
Page 68: ...Page 68 IQ Radar 160 160 Ex PL 550 Appendix II ...
Page 74: ...Page 74 IQ Radar 160 160 Ex PL 550 Appendix III ...