PL-601
EnviroRanger Installation Guide
Page 17
In
s
ta
lla
tio
n
6. Press fit the terminal board to the EnviroRanger. To ensure that the pressure
on the rear of the unit is minimized, provide external support for the wires.
Wall Mount
Notes:
•
We recommend mounting the unit on ¾” plywood using #6 screws.
•
If another mounting surface is used, it MUST be able to support four
times the weight of the unit.
1. Mark and drill holes for the four mounting screws (customer supplied), and
mount the enclosure using a long screwdriver.
If your cable is routed through a conduit:
2. Unplug the display ribbon cable from the motherboard.
3. Remove the four mounting screws holding the motherboard to the enclosure.
4. Be careful not to damage the electronics with static electricity. Remove the
motherboard from the enclosure by pulling the board straight out and tilting it
with the right side higher to clear the ferrite assembly.
5. Drill any required cable entry holes.
6. Attach the conduit to the enclosure using approved Conduit Entrance Hubs.
7. Reinstall the motherboard with the mounting screws and attach ribbon cable.
209mm
(8.2”)
172mm
(6.8”)
15mm
(0.6”)
267mm
(10.5”)
285mm
(11.2”)
102mm
(4.0”)
mounting holes
(4 places)
28mm
(1.1”)