AiRanger XPL Plus – INSTRUCTION MANUAL
7ML19981AN02
mmm
mm
Te
c
hnical Ref
e
re
nce
Status A
1 character, $0 to $F (convert to binary, e.g. temp, echo, and cable OK, not
priority)
Status B
1 character, $0 to $F (convert to binary, e.g. scan point is in high alarm)
Status C
1 character, $0 to $F (convert to binary, e.g. scan point is not in rate or
band alarm)
Temp
2 characters, $32 to $FA (convert to decimal and subtract 100, e.g.
temperature = 20 °C)
Percent
5 characters, 00.00 to 9999. (e.g. current level = 85.00% of span, EEEE. =
field overflow)
CR
$0D (End Of Message)
Field Name
Definition
STX
$02 (Start Of Message)
Message Type 2 characters, 00 (indicates the following data pertains to a scan point
measurement)
Point #
3 characters, 001 to 010 (e.g. the message pertains to Point Number 1)
Reading
5 characters, 0.000 to 9999. (e.g. reading = 678.9, DDDD. = no data,
EEEE. = overflow)
####
1 = temp alarm
1 = loss of echo (f.s. expired)
1 = transducer cable fault
1 = priority point
MSB
LSB
####
1 = low low alarm
1 = low alarm
1 = high alarm
1 = high high alarm
MSB
LSB
####
1 = rate alarm 2
1 = rate alarm 1
1 = band alarm 1
1 = band alarm 2
MSB
LSB
Summary of Contents for airanger XPL plus
Page 1: ...Instruction Manual March 2005 XPL PLUS airanger ...
Page 10: ...Page 6 AiRanger XPL Plus INSTRUCTION MANUAL 7ML19981AN02 ...
Page 26: ...Page 22 AiRanger XPL Plus INSTRUCTION MANUAL 7ML19981AN02 ...
Page 82: ...Page 78 AiRanger XPL Plus INSTRUCTION MANUAL 7ML19981AN02 ...
Page 106: ...Page 102 AiRanger XPL Plus INSTRUCTION MANUAL 7ML19981AN02 ...
Page 113: ......