Page 66
AiRanger XPL Plus – INSTRUCTION MANUAL
7ML19981AN02
mmmm
m
Enhancement P
a
ra
met
e
rs
PROFILE POINTER PARAMETERS
When a Profile Pointer Parameter is accessed, the Echo Lock Window scope
display changes to a Profile Pointer display. The Profile Pointer may be moved to
a number of points on the Echo Profile, to gain specific information dependent
upon the Profile Pointer Parameter used.
To move the Profile Pointer to a specific point, enter the desired value. The
Profile Pointer will move to the nearest acceptable Echo Profile point. The
Profile Pointer is preset to "0".
Alternatively, to scroll the Profile Pointer along the Echo Profile
1. Press
to display the Auxiliary Function symbol.
2.
or
to move the Profile Pointer to the left or right respectively.
When the Profile Pointer Parameters are exited and
is pressed or the RUN
mode is entered, the Profile Pointer display automatically changes back to the
Echo Lock Window display.
P817 (V) PROFILE POINTER TIME
Observe the time (in ms) between the transmit pulse and the Profile Pointer.
values: 0.000 to 9999
P818 (V) PROFILE POINTER DISTANCE
Observe the distance (in P005 Units) between the transducer face and the
Profile Pointer.
values: 0.000 to 9999
P819 (V) PROFILE POINTER AMPLITUDE
Observe the amplitude (in dB above 1µV) of the Echo Profile at the Profile Pointer
position.
values: 0 to 99
P
P
Summary of Contents for airanger XPL plus
Page 1: ...Instruction Manual March 2005 XPL PLUS airanger ...
Page 10: ...Page 6 AiRanger XPL Plus INSTRUCTION MANUAL 7ML19981AN02 ...
Page 26: ...Page 22 AiRanger XPL Plus INSTRUCTION MANUAL 7ML19981AN02 ...
Page 82: ...Page 78 AiRanger XPL Plus INSTRUCTION MANUAL 7ML19981AN02 ...
Page 106: ...Page 102 AiRanger XPL Plus INSTRUCTION MANUAL 7ML19981AN02 ...
Page 113: ......