Mills A-WAH09 Installation And Instruction Manual Download Page 1

INSTALLATION AND INSTRUCTION MANUAL

 LED AREA LUMINAIRE

PLEASE READ ALL INSTRUCTIONS BEFORE 

ATTEMPTING INSTALLATION

 

» To prevent personal injury or product damage only licensed electricians  

should install.

 

» To avoid electric shock or component damage disconnect power before 

attempting installation or servicing.

 

» This product must be installed in accordance with the national electric code (NEC) 

and all applicable federal, state and local electric codes and safety standards.

 

» Disconnect product and allow cooling prior to servicing.

 

»

Any alteration or modification of this product is expressly forbidden as it 

may cause serious personal injury, death, property damage and/or product 
malfunction.

 

» To prevent product malfunction and/or electrical shock this product must be 

properly grounded.

 

» This luminaire is designed to operate in ambient temperatures ranging from -40°C 

to 45°C and to be horizontally mounted with the LEDs facing down.

 

» This product must be installed in accordance with the applicable installation code 

by a Person familiar with the construction and operation of the product and the 
hazards involved.

 

» MIN 75°C SUPPLY CONDUCTORS

 

» CONSULT A QUALIFIED ELECTRICIAN TO ENSURE CORRECT BRANCH 

CIRCUIT CONDUCTOR

 

» CAUTION - RISK OF FIRE

 

»

Slipfitter Mounted with PHOTOCELL function elevation angle should not exceed 

15 degrees

Black

White

Neutral

Green/Yellow Green

Ground

Line

Purple

DIM+

Gray

DIM-

BLACK

BL

AC

K

BL

AC

K

INPUT

LAMPLOAD

RED

PHOTOCONTROL

MOTION SENSOR

WHITE

WHIT

E

WHIT

E

WARNING

(Figure 1)

 Twisted photocell (optional)

PM4*12(mm) Screws

Side plate

OPEN

Mounting bracket

 5/16’’*1.02(inch) UNC Screws

1/2’’*1.97(inch) 

UNC Screws

Round pole 

mounting plate

Motion Sensor (optional)

PM4*8(mm) 

Screws

Side plate

(Figure 2)

5/16’’*1.02(inch) UNC Screws

 Twisted photocell (optional)

M8*20(mm) Screws

PM4*12(mm) Screws

(Figure 3)

5/16’’*1.02(inch) UNC Screws

 Twisted photocell (optional)

PM4*8(mm) Screws

Motion Sensor (optional)

Back plate

Side plate

1/2’’1.46(inch) UNC Screws

PM4*12(mm) Screws

KM4*10(mm) Screws

OPEN

Square/Round Pole

1.  Remove the side plate from mounting bracket. Please skip to step 3 if mounted 

onto the square Pole.

2.  Attach round pole mounting plate on mounting bracket.
3. 

Route the cord into mounting bracket through the hole for wiring, slide the fixture 

onto the bracket and tighten 2 bottom screws.

4.  Slightly drag the wires to make sure the hole on bracket is sealed by  

silicon gasket.

5.  Make wiring connection as per wire diagram below, replace the side plate and 

fasten screws.

Slipfitter

1.  Connect the wires to L / N / GND
2.  Remove the cover and adjust the bracket to the desired angle
3. 

Install the bracket on the pole and fix it with screws

Wall Mount

1.  Remove the side plate by loosen the screws.
2. 

Fix the back plate onto the arm bracket with screws provided.

3.  Use the metal template provided to locate footprint on the wall  to drill the holes, 

then fix the bracket on the wall with screws.

4. 

Route the power cord into wall mount bracket, slide the fixture  onto the mounting 

bracket, then tighten bottom screws.

5.  Make wiring connection inside of bracket and replace the side plate with screws.

Reviews: