Page 1: ...VHP Resistant Pump The life science business of Merck KGaA Darmstadt Germany operates as MilliporeSigma in the U S and Canada Millipore VHP ON C OK START OF F Millipore VHP ON C OK START OF F Millipo...

Page 2: ...iltrating hazardous liquids wear and use proper protective clothing and equipment for the handling and the disposal of the liquid to be filtrated The system power cord is the main system disconnecting...

Page 3: ...e pumps with the manifold tray The pump comes with the following documents User Guide PF12640 Certificate of conformity for the pump MXPPLUVHPCOQ and the pump head MXPHEAVHPCOQ Note The VHP resistant...

Page 4: ...electrical parts electrical hub cables set and power supply Some components for the fluidic parts fluidic hub and tubes set MXPELEHUB Milliflex electrical hub VHP compatible MXPFHUVHP Milliflex fluidi...

Page 5: ...upply set is composed of A power supply A fluidic tube 5 System installation A Single pump system Connect the supply set fluidic tube and power cable to the VHP pump as follows Millipore VHP ON C OK S...

Page 6: ...umps together before placing the system in the isolator The use of the tray facilitates the transfer of the assembled system to the isolator Caution when assembled the system is heavy 14 3 kg without...

Page 7: ...with the tray Put in place the tray Fix each pump one by one to the tray using the fast screw V H P R e si st a n t V H P R e si st a n t V H P R e si st a n t V H P R e si st a n t V H P R e si st a...

Page 8: ...to each pump Detail of the electrical connection Once all the connections are in place reverse the whole system using the manifold tray Take care not to crush the fluidic tubes and electric cables wh...

Page 9: ...9 V H P R es is ta nt V H P R es is ta nt V H P R es is ta nt Millipore VHP ON C OK STAR T OFF Millipore VHP ON C OK STAR T OFF Millipore VHP ON C OK START OFF 1 2 3...

Page 10: ...p to three Milliflex PLUS pumps Fluid Line Connections Push the Milliflex PLUS Pump fluid line connectors into the fluid hub until a click is heard Install the other end of the tubing onto the pumps I...

Page 11: ...until a click is heard Connect the other end of the cables onto the pumps Connect the power supply to the electrical hub and tighten the connector To disconnect the electrical cables from the hub pul...

Page 12: ...ycle as shown below 3 Pump head installation Push in the latch on the side of the pump head Place the pump head onto the mounting post with the latch to the left as you face the pump as shown Turn the...

Page 13: ...ivered with the pump head does NOT ensure VHP resistance of the pump 4 Typical installation Millipore VHP ON C OK START OFF Millipore VHP ON C OK START OFF Millipore VHP ON C OK START OFF 6 Controls a...

Page 14: ...Con guration Buzzer Buzzer ON Buzzer OFF Validation Weight calibration Time veri cation nber of cycle since last calib xx Vacuum veri cation For maintenance only For maintenance only For maintenance o...

Page 15: ...all the pump head as described in the Installation section Run the Tare cycle as described below 2 To prepare for testing switch on the pump by pressing the ON OFF button on the keypad For a few secon...

Page 16: ...own 16 Wipe the pump head with an aseptic wipe D Sanitizing The pump interior should be sanitized before its first use after each workday and if unused for more than a day The Sanitizing cycle enables...

Page 17: ...total of four rinses When the fourth rinse has been completed the display shows Sanitizing finished Press start 12 Press START Remove the funnel and discard it The display shows Sanitizing 13 Press C...

Page 18: ...pply output 24 V VDC 3 0 A Pump input 24 VDC Pump power 25 VA Electrical Hub 24 VDC 75 VA Vacuum 0 4 bar 11 8 inches of Hg Flow rate 7 to 16 seconds for 100 mL of Milli Q grade sterile water filtered...

Page 19: ...VHP 1 FTPF01866 Power cord for Europe FTPF02471 Power cord for North America Central America Brazil Mexico SIMCABLE1 Power cord for United Kigdom Ireland Malaysia Singapore Hong Kong SIMCABLE2 Power...

Page 20: ...f certain Hazardous Substances RoHS in electrical and electronic equipment In accordance to the European Union Directive 2012 19 EC on Waste Electric and Electronic Equipment the presence of this logo...