A complete Parts List is available at www.MillerWelds.com
OM-4426 Page 46
!
Stop engine.
Open left side door.
When a supplementary protec-
tor or fuse opens, it usually in-
dicates a more serious prob-
lem exists. Contact a Factory
Authorized Service Agent.
1
Supplementary Protector CB4
CB4 protects the stator winding
supplying 24 volt AC output to Re-
mote receptacle RC4. If CB4
opens, 24 volt AC output to RC4
stops.
Supplementary protectors
CB1 and CB3 protect the stator
winding supplying 115 volt AC
output to Remote Receptacle
RC4 (see Section 7-1).
Press button to reset.
2
Fuse F6 (See Parts List)
F6 protects the engine wiring sys-
tem from overload. If F6 opens,
engine will not crank.
Replace fuse if open.
Close left side door.
803 773
−
A / Ref. 216 170 / 161 001
8-11. Overload Protection
2
1