A complete Parts List is available at www.MillerWelds.com
OM-4426 Page 21
SECTION 5
−
INSTALLATION
5-1. Serial Number And Rating Label Location
The serial number and rating information for this product is located on
the back.
Use rating label to determine input power requirements and/or rated
output. For future reference, write serial number in space provided on back cover of this manual.
!
Do not move or operate unit
where it could tip.
!
Do not lift unit from end.
!
Do not weld on base. Welding
on base can cause fuel tank fire
or explosion. Bolt unit down
using holes provided in base.
!
Always securely fasten weld-
ing generator onto transport
vehicle or trailer and comply
with all DOT and other applica-
ble codes.
NOTICE
−
Do not install unit where air
flow is restricted or engine may over-
heat.
See Section 4-3 for lifting eye rat-
ing.
Mounting:
!
Do not mount unit by support-
ing the base only at the four
mounting holes. Do not use
flexible mounts. Use cross-
supports to adequately sup-
port unit and prevent damage
to base.
1
Cross-Supports
Mount unit on flat surface or use
cross-supports to support base,see
Section 4-3.
install2 2008-01
−
Ref. 800 652 / Ref. 800 477-A / 803 274-A / 804 712
OR
18 in.
(460 mm)
18 in.
(460 mm)
18 in.
(460 mm)
18 in.
(460 mm)
18 in.
(460 mm)
OR
Movement
Location / Airflow Clearance
5-2. Installing Welding Generator
Mounting
OR
1