OM-262379 Page 21
6-3.
Wire Speed Dual Schedule
265 376-A / 265 377-A
Wire Speed Dual Schedule allows the oper-
ator to switch between standard wire speed
and a reduced wire speed. When activated,
the reduced wire speed will be 87.5% of the
standard wire speed. Wire Speed Dual
Schedule may be activated any time before
or during the weld by using a gun with an in-
ternally mounted dual schedule switch, or a
gun with an added dual schedule switch. If
the feeder is equipped with Wire Speed
Meter it will display the active wire speed,
whether it is standard wire speed or reduced
wire speed.
Weld Gun With Internal Mounted Dual
Schedule Switch Comparable To
PipePro
Dura−Flux
Gun.
1
Gun Trigger Receptacle
2
Gun Trigger Plug
Connect gun trigger plug to gun trigger
receptacle.
Weld Gun With Internal Mounted
Dual Schedule Switch
Weld Gun With External Mounted
Dual Schedule Switch
2
1
4
5
6
3
Weld Gun With External Mounted Dual
Schedule Switch Comparable To
DSS−9−15 (071833)
3
Gun Trigger Receptacle
4
Dual Schedule Plug
5
Dual Schedule Switch Receptacle
6
Gun Trigger Plug
Connect gun trigger plug to dual schedule
switch receptacle . Connect dual schedule
plug to gun trigger receptacle.