OM-287388 Page 12
4-6. Optional Meter Circuit Board Settings
805 228-A
Tools Needed:
Torx 25
1
Meter Circuit Board
2
DIP Switch S2
Set DIP switch S2 for type of
welding power source, and desired
wire feed speed display (see
illustration).
Reinstall wrapper.
1
2
X Indicates switch position does not affect
specified function.
.
Means switch must be in this position.
2
1
Digital Amperage Display
Hold Function ON
Hold Function OFF
1
2
3
4
S2
1
2
3
4
Voltage Measurement
0-100V
Current Signal
1
2
3
4
1
2
3
4
1
2
3
4
(Step Voltage Power Source)
Signal Not Available
Wire Feed Speed Display
Inches/Minute
1
2
3
4
1
2
3
4
1
2
3
4
Or
0-10V
(Electronic Control P/Source)
Or
Or
Or
Signal Available
Meters/Minute
1
2
3
4