OM-246 466 Page 43
4-15. Reset Mode
198 993 / Ref. 803 246-B
.
Reset mode is not active when
Program Lock is enabled.
The reset mode allows the operator to
reload factory program settings for all
eight active programs in the unit.
.
System configuration data will be
lost during the Reset operation.
Rotate Adjust knob to change NO
to YES.
Program 1
RMD-Pro
.045 Mild Steel E70
75% Argon, 25% CO
2
Program 2
RMD-Pro
.035 Metal Core E70
75% Argon, 25% CO
2
Program 3
RMD-Pro
.045 Metal Core 71
85% Argon, 15% CO
2
Program 4
RMD-Pro
.045 Metal Core 71
90% Argon, 10% CO
2
Program 5
GMAW
.035 Mild Steel E70
75% Argon, 25% CO
2
Program 6
SMAW
EXX10
Program 7
SMAW
EXX18
Program 8
Lift TIG
Press the Arc Control button to
confirm the reset.
The reset message is displayed for
2 seconds while factory program
settings are being reloaded.
During the reset mode the following
factory default programs are loaded
into the unit:
Cycl Pwr message appears on the display
when programs complete loading.
Turn power off, wait 10 seconds, and turn
power back on again to complete the reset
operation.
.
After Reset is complete, be sure to load
appropriate programs that contain the
correct wire size, process, and shielding gas
for the welding operation
CYCL
PWR
RST
YES
RST
YES
Enter reset mode by turning power On and pressing the Program Push Button until the
RST NO message is displayed. RST NO message will not display until after the
power-up sequence is completed (approximately 20 seconds).
RST
NO