A complete Parts List is available at www.MillerWelds.com
OM-253392 Page 18
5-4. Process/Polarity Table
Process
Polarity
Cable Connections
Wire Drive Assembly Cable
Work Cable
GMAW
−
Solid wire with shielding gas
DCEP
−
Reverse polarity
Connect to positive (+) out-
put receptacle
Connect to negative (
−
) out-
put receptacle
FCAW
−
Self-shielding wire
−
no shielding
gas
DCEN
−
Straight Polarity
Connect to negative (
−
) out-
put receptacle
Connect to positive (+) out-
put receptacle
5-5. Wire Welding Connections
Ref. 254 252-B / Ref. 254 249-C / Ref. 254 247-B
!
Turn off unit and disconnect input
power before making connections.
!
Do not use worn, damaged, under-
sized, or repaired cables.
1
Positive Weld Output Receptacle
2
Negative Weld Output Receptacle
3
Wire Drive Assembly Cable
4
Work Clamp And Cable
Ensure all connections are tight.
5
Gun End
Connect gun end to drive assembly (see
Section 5-6).
6
Trigger Control Cable
7
Four Pin Trigger Control Cable
Receptacle
Route trigger control cable through MIG
gun hole.
Connect plug on end of cable to four pin
receptacle inside unit.
8
MIG Shielding Gas Connection
Use 75/25 mix or CO
2
shielding gas for
solid wire. Use Argon shielding gas for
aluminum wire with spool gun (see Section
5-7).
MIG
−
DCEP
(Direct Current Electrode Positive)
Flux-Cored
−
DCEN
(Direct Current Electrode Negative)
1
4
3
2
1
4
3
2
8
6
7
5