OM-261050 Page 40
1
2
9-2. EnVerter
Power System Connections And Overload Protection
265 802-A / 287 066 / 287 097-D
!
Stop engine and let cool.
!
Keep wiring away from hot, sharp, or
moving parts.
1
Terminal Block 1T
120 VAC EnVerter
power is available
between 1TF and 1TD.
Combined output of all EnVerter power loads
cannot exceed 2.4 kVA/kW. Full EnVerter
power is available regardless of engine
speed.
Route conductors through strain relief in right
side of unit to auxiliary power box for connec-
tion.
NOTICE
−
There are two options for installing
120 VAC power, see truck wiring diagrams
2
Supplementary Protector CB2
Supplementary protector CB2 protects the
EnVerter power supply from overload when a
120 VAC load is connected.
If supplementary protector continues to
open, contact Factory Authorized Ser-
vice Agent.
Tools Needed:
240V
120V
120V
F E D
C
B
120V/60HZ
120V/240V
NEUTRAL
NEUTRAL
GROUND
120V/240V
EnVerter
SUPPLY
120V/60HZ
NEUTRAL
BONDED
TOFRAME
A
Route leads from EnVerter
load through strain relief.