4-12. Hydraulic Pressure Flow Curves
−
Combination Loads
(Models With Hydraulic Power Source)
261 044-A
Curves are typical. Output will
vary depending on system
pressure losses to load sense
pressure location.
Fluid: ISO 32 Hydraulic Oil
Fluid Temperature: 49
°
C (120
°
F)
Load Sense Pressure:
Closed Center
−
400 PSID
(27.6 bar)
Open Center
−
200 PSID (13.8
bar)
0
10
20
30
40
50
60
0
2
4
6
8
10
12
14
16
0
500
1000
1500
2000
2500
3000
3500
A
ir
Flow @ 100psi (scfm)
Hydraulic Flow (gpm)
Hydraulic Pressure (psi)
Pump Flow with Compressor
Pump Flow with 6kW
Air Compressor Flow
Open Center Hydraulic Pressure
−
Flow Curves (Combination Loads)
0
10
20
30
40
50
60
0
2
4
6
8
10
12
14
16
18
20
A
ir
Flow
@
100psi
(
sc
fm
)
Hydraulic
Flow
(
g
p
m
)
Hydraulic Pressure (psi)
Pump Flow with Compressor
Pump Flow with 6kW
Air Compressor Flow
Closed Center Hydraulic Pressure
−
Flow Curves (Combination Loads)
0
500
1000
1500
2000
2500
3000
3500
Summary of Contents for ENPAK
Page 47: ...OM 261050 Page 43 10 2 Remote Panel Use With Section 10 3 248 998 1 2 6 3 4 5 7 8 9 10 11...
Page 64: ...OM 261050 Page 60 SECTION 13 DIAGRAMS Figure 13 1 Training Circuit Diagram For EnPak...
Page 65: ...OM 261050 Page 61 261 040 D...
Page 66: ...OM 261050 Page 62 257 926 C Figure 13 2 EnPak Circuit Diagram...
Page 67: ...OM 261050 Page 63 261 045 A Figure 13 3 Air Compressor Diagram...
Page 79: ...OM 261050 Page 75 Notes...
Page 94: ...OM 261050 Page 90 Notes...