OM-261050 Page 64
Ref. 242 500-F
Figure 13-4. EnPak Truck Wiring Diagram Option 1
265 533-B
NOTICE
−
If the high speed (3600 RPM) 120 V / 20 A circuit is placed in ser-
vice on the truck, the following items apply:
CB3 supplementary breaker to be installed in auxiliary power enclosure, it
must match the amperage rating of the receptacle. CAUTION: If a GFCI re-
ceptacle is installed, it must be a MILLER-recommended GFCI receptacle.
The generator does not provide useable power at engine idle speed (1800
RPM). Other GFCI receptacles cannot be used. The low frequency / low
voltage may prevent other GFCI receptacles from operating properly.
NOTICE
−
240 V circuit and EnVerter power are protected at the listed cur-
rent by supplementary protectors located next to 1T inside EnPak. Any type
GFCI may be used for the EnVerter 120 V circuit. If a plug-in adapter is used
to split 120 VAC from the 240 VAC receptacle, it must follow the same guide-
lines as Notice above.
Figure 13-5. EnPak Truck Wiring Diagram Option 2
Summary of Contents for ENPAK
Page 47: ...OM 261050 Page 43 10 2 Remote Panel Use With Section 10 3 248 998 1 2 6 3 4 5 7 8 9 10 11...
Page 64: ...OM 261050 Page 60 SECTION 13 DIAGRAMS Figure 13 1 Training Circuit Diagram For EnPak...
Page 65: ...OM 261050 Page 61 261 040 D...
Page 66: ...OM 261050 Page 62 257 926 C Figure 13 2 EnPak Circuit Diagram...
Page 67: ...OM 261050 Page 63 261 045 A Figure 13 3 Air Compressor Diagram...
Page 79: ...OM 261050 Page 75 Notes...
Page 94: ...OM 261050 Page 90 Notes...