OM-261050 Page 57
Trouble
Remedy
Engine does not return to idle speed.
Remove all generator power loads, compressor loads, and hydraulic loads.
Check remote panel and crane pendant to see if system is locked in high speed.
Ambient temperature may be below 50
°
F, and engine temperature may be less than 100
°
F. Warm up
engine to 100
°
F.
Have Factory Authorized Service Agent check circuit board PC1 and current transformer CT1.
Engine speed does not remain con-
stant.
GFCI receptacle is not proper type for application. Replace with Miller approved GFCI device (Con-
tact Factory).
Engine overheats.
Check error messages. Check oil and coolant levels.
Engine coolant temperature low.
Have Factory Authorized Service Agent check engine thermostat for proper operation. Replace if
necessary.
During operation in severe cold weather it may be necessary to restrict inlet cooling air by partially
blocking unit air inlet louvers. Do not restrict engine combustion air inlet or engine exhaust or exit
cooling air. Remove restriction when severe cold weather ends to prevent engine overheating.
Engine does not remain at power
speed when a load is applied with
crane pendant speed switch in the Low
or Idle position.
For small loads, place crane pendant speed control switch in the High or Fast position, or push Power
Start button on remote control panel to lock in high speed.
During operation in severe cold weath-
er, engine starts and goes to idle but
stalls after a few minutes.
Normal maximum glow plug time is 3 to 10 seconds for temperatures from 50
°
F down to 0
°
F. In ambi-
ent temperatures below 0
°
F, glow plug time is 13 seconds maximum. Check glow plug timing to en-
sure proper heating before cranking engine.
12-3. Compressor Troubleshooting
Trouble
Remedy
Air compressor does not operate; no air
pressure on gauge.
Cycle compressor to on position.
Check compressor belt tension. Be sure correct belt is used and is properly installed.
Have Factory Authorized Service Agent check inlet valve P-IC1.
Have Factory Authorized Service Agent check air compressor control circuit and clutch.
Air compressor stops during normal use. Automatic shutdown stops compressor if compressor temperature is too high or over
−
pressure condition
occurs.
Check compressor oil level (see Section 8-3). Check for clogged oil cooler. Clean debris from oil cooler.
Recirculation or open covers may cause overheating. Be sure all covers, panels, and doors are in place.
Operate in area with proper airflow.
Check for over-pressure condition by turning on compressor and monitoring air pressure and remote dis-
play for error messages.
Low air pressure.
Check for leaks in air lines and hoses, including control line.
Adjust compressor air pressure using the EnPak Remote Panel.
Check air compressor air cleaner (see Section 11-5).
Have Factory Authorized Service Agent check compressor for rated output.
High air pressure.
Adjust compressor air pressure using the EnPak Remote Panel.
Be sure control line is connected at valve manifold and Intake Control Valve (P
−
IC1).
Check for frozen manifold, Intake Control Valve (P
−
IC1), and/or Proportional Flow Control Valve
(P
−
FC1).
Oil in air from compressor.
Check compressor oil level (see Section 8-3). If oil level is too high, system becomes saturated with oil.
Change compressor air/oil separator if close to replacement hours (see Section 11-5).
Summary of Contents for ENPAK
Page 47: ...OM 261050 Page 43 10 2 Remote Panel Use With Section 10 3 248 998 1 2 6 3 4 5 7 8 9 10 11...
Page 64: ...OM 261050 Page 60 SECTION 13 DIAGRAMS Figure 13 1 Training Circuit Diagram For EnPak...
Page 65: ...OM 261050 Page 61 261 040 D...
Page 66: ...OM 261050 Page 62 257 926 C Figure 13 2 EnPak Circuit Diagram...
Page 67: ...OM 261050 Page 63 261 045 A Figure 13 3 Air Compressor Diagram...
Page 79: ...OM 261050 Page 75 Notes...
Page 94: ...OM 261050 Page 90 Notes...