OM-2240 Page 53
6-6. Stick Open-Circuit Voltage (OCV) Selection (All Models)
1
Process Switch Pad
2
Adjust Switch Pad
3
Amperage Switch Pad
4
Power Switch
To access the Stick OCV selection,
turn power switch on and then press
the Process, Adjust and Amperage
switch pads before the software ver-
sion clears the meters. Hold the switch
pads until
[SEL] [L
oc
]
or
[SEL] [
noc
)
appears.
5
Encoder Control
6
Meter Display
Turn Encoder to change between low
OCV
[SEL] [L
oc
]
and normal OCV
[SEL]
[
noc
]
. Active selection is displayed on
the meters.
When Stick low OCV is selected, open-
circuit voltage is between 9 and 14
volts. When Stick normal OCV is se-
lected, open-circuit voltage is approxi-
mately 80 volts.
Application:
For most Stick applica-
tions use low open-circuit voltage. Use
normal open-circuit voltage for hard to
start Stick electrodes, or if required for
your particular application.
sel
2
And
5
1
Rear Panel
V
Or
l
oc
3
4
6