OM-273473 Page 12
SECTION 4 − SPECIFICATIONS
4-1.
Serial Number And Rating Label Location
The serial number and rating information for this product is located on the back. Use rating label to determine input power requirements and/or rated
output. For future reference, write serial number in space provided on back cover of this manual.
4-2.
350 Model Specifications
.
Do not use information in unit specifications table to determine electrical service requirements. See Sections 5-10 and 5-11 for information on
connecting input power.
.
This equipment will deliver rated output at an ambient air temperature up to 104
5
F ( 40
5
C).
Input
Power
Rated
Welding
Output
Voltage
Range
CV Mode
Amperage
Range
CC Mode
Max
Open
Circuit
Voltage
DC
Amperes Input At Rated Load Output 60 Hz,
Three-Phase
Input
kVA
Input
KW
230 V
380 V
400 V
460 V
575 V
Three
Phase
350 A @
34 V DC,
100%
Duty
Cycle
10-44 V
20-400 A
75
36.7
(0-1A*)
21.8
(0-1A*)
20.8
(0-1A*)
18.8
(0-1A*)
14.6
(0-1A*)
14.4
(0.8*)
13.8
(0.17*)
*While idling; Input amperage fluctuates while idling and is always less than one Ampere. Use one Ampere for power efficiency calculations.
4-3.
500 Model Specifications
.
Do not use information in unit specifications table to determine electrical service requirements. See Sections 5-10 and 5-11 for information on
connecting input power.
.
This equipment will deliver rated output at an ambient air temperature up to 104
5
F ( 40
5
C).
Input
Power
Rated
Welding
Output
Voltage
Range
CV Mode
Amperage
Range
CC Mode
Max
Open
Circuit
Voltage
DC
Amperes Input At Rated Load Output 60 Hz,
Three-Phase
Input
kVA
Input
KW
230 V
380 V
400 V
460 V
575 V
Three
Phase
500 A @
40 V DC,
100%
Duty
Cycle
10-44 V
20-600 A
75
58.7
(0-1A*)
34.9
(0-1A*)
33.2
(0-1A*)
28.9
(0-1A*)
23.3
(0-1A*)
23.1
(0.8*)
21.9
(0.17*)
*While idling; Input amperage fluctuates while idling and is always less than one Ampere. Use one Ampere for power efficiency calculations.
Summary of Contents for Auto-Continuum 350
Page 55: ...OM 273473 Page 51 273 905 B...
Page 56: ...OM 273473 Page 52 Figure 10 2 Circuit Diagram For Auto Continuum 350 Model Page 2 of 2...
Page 57: ...OM 273473 Page 53 273 905 B...
Page 58: ...OM 273473 Page 54 Figure 10 3 Circuit Diagram For Auto Contiuum 500 Model Page 1 of 2...
Page 59: ...OM 273473 Page 55 273 490 B...
Page 60: ...OM 273473 Page 56 Figure 10 4 Circuit Diagram For Auto Continuum 500 Model Page 2 of 2...
Page 61: ...OM 273473 Page 57 273 490 B...
Page 67: ...OM 273473 Page 63 Notes...
Page 72: ...Notes...
Page 73: ...Notes...
Page 74: ...Notes...