OM-478 Page 28
SECTION 7
−
OPERATING OPTIONAL BATTERY CHARGER
Follow jump starting procedure to quickly start equipment having a weak or dead
battery. Follow charging procedure to trickle-charge a battery.
NOTE
7-1. Jump Start/Battery Charge Cable Connections
ST-153 653-A
Stop engine.
Do not charge or jump start a
battery which has loose ter-
minals or one showing dam-
age such as a cracked case
or cover.
Have only qualified persons
do battery charging work.
Keep cables away from
moving parts.
Do not use damaged cables.
Read supplied BCI Battery
Service Manual before
charging or jump starting.
1
Jump Start/Battery Charge
Plug
2
Red (+) Cable
3
Black (
−
) Cable
Obtain cable with proper
connectors.
4
Remote Momentary-On
Switch And Plug
Remote switch is used only for
jump starting a battery. Press
switch to turn jump starting output
on. Release switch to turn output
off.
Open lower access door. Route
cable as shown. Insert plug into
Remote 14 receptacle, and tighten
threaded collar. Close door.
5
Cover
6
Jump Start/Battery Charge
Receptacle
Remove cover, and insert plug in
receptacle. Connect remaining end
of cable to equipment being jump-
started or charged. Use correct
polarity (+ and
−
) when making con-
nections.
Tools Needed:
3/8 in
1
2
5
6
3
4
Summary of Contents for Air Pak
Page 4: ......
Page 25: ...OM 478 Page 21 Notes...
Page 46: ...OM 478 Page 42 SECTION 9 ELECTRICAL DIAGRAMS Figure 9 1 Circuit Diagram For Welding Generator...
Page 47: ...OM 478 Page 43 SD 194 053...
Page 48: ...OM 478 Page 44 Figure 9 2 Circuit Diagram For Welding Generator With Optional Battery Charger...
Page 49: ...OM 478 Page 45 SD 194 061...
Page 51: ...OM 478 Page 47 SD 194 062...
Page 83: ...Notes...
Page 84: ...Notes...