![Miller 907684001 Owner'S Manual Download Page 72](http://html1.mh-extra.com/html/miller/907684001/907684001_owners-manual_1796041072.webp)
.
A complete Parts List is available at www.MillerWelds.com
OM-270536 Page 64
11-5. Lockout Functions
OFF
1
2
LOCK
CODE
See Section 11-2 for information on how
to access Lockout Functions.
There are four (1
−
4) different lockout
levels. Each successive level allows the
operator more flexibility.
.
Before activating lockout levels, be
sure that all procedures and
parameters are established.
Parameter adjustment is limited
while lockout levels are active.
To turn On lockout feature, proceed as
follows:
1
Amperage Adjustment Control
2
Amperage (A) Control
Press Amperage (A) control to toggle
between the lock off and code off
displays. Toggle control until [CODE]
[OFF] is displayed
Turn amperage adjustment control to se-
lect a lockout code number. Select a num-
ber between 1 and 999. The number will
appear on the amperage, right, display.
.
Remember (write down) this code
number, as you will need this number
to turn this feature off, or make
changes to your settings.
Toggle Amperage control until [LOCK] is
displayed. You may now select a lockout
level. See table below for the degree of
adjustability associated with each lock
level. Exit Advanced Functions
according to Section 11-2.
To turn Off lockout feature, proceed as
follows:
Toggle Amperage control until Code is
displayed.
Use amperage adjustment control control
to enter the same code number that was
used to turn on the lockout feature.
Press the Amperage control. The am-
perage meter display will turn to [OFF].
Lockout is now off. Exit Advanced
Functions according to Section 11-2.
247220-D
11-6. Lockout Levels Defined
Minimum Adjustability
Degree Of Adjustability
Maximum Adjustability
Lock Level 1
Lock Level 2
Lock Level 3
Lock Level 4
Adjustable
Locked
Adjustable
Locked
Adjustable
Locked
Adjustable
Locked
Panel Amps
Panel Amps
Panel Amps +/- 10%
Remote Amps
(min
−
panel)
Panel Amps +/- 10%
Polarity (Dyn Only)
Polarity (Dyn Only)
Polarity (Dyn Only)
Polarity (Dyn Only)
Process
Process
Process
Process
Output
Output
Output
Output
Pulser
Pulser
Pulser (on/off only)
Pulser (on/off only)
Sequencer
Sequencer
Sequencer
Sequencer
Gas/DIG
Gas/DIG
Gas/DIG
Gas/DIG
Waveshape
Waveshape
Waveshape
Waveshape
Summary of Contents for 907684001