OM-222166 Page 48
8-3-3.
Finishing Procedure
1.
If ProHeat 35 was set for Temp in Control Mode follow steps 8-3-1, steps 4.−6. to change it back to Temp.
2.
Turn ProHeat 35 power switch off.
3.
Have qualified person disconnect primary power.
4.
Remove precision DVM and TC calibrator.
5.
Complete calibration label & place it on unit directly above TC1 display.
I.D. No. (TC board serial number) Be sure the serial number matches the board in the machine.
By (your initials) Date (today’s date)
Due (date 1 year from today)
6.
Print a copy of the certificate to send with the ProHeat 35.
7.
If entering data in a spreadsheet, save data.