OM-222166 Page 36
7-5-2.
Remote Control
Remote Control operates the system from a remote device which energizes or de−energizes output as well as setting the desired output power level
as a function of the maximum output power setting in the system setup screen. The run button on the front of the ProHeat 35 is disabled in remote
mode.
If Remote was selected as the control mode in the system setup screen, the following screen appears for programming:
Mode....: Remote Power..: 0.0 KW
Run Time:>00:03:00 Current: 0 A
Voltage: 0 V
Frequency: 4.5 KHz
Time is the only parameter that can be set. The values are 0 − 99:59:59.
.
The Run button on the front of the power source is disabled in this mode. Use remote device to toggle output On or off.
7-5-3.
Power vs Time Control
Power vs Time control operates the system and controls the heating process based on programmed time and power. Power increases over a pro-
grammed amount of time.
Press the Program button to access the programming mode. Use the cursor button to move the cursor between Mode, Segment, Type, Power, and
Time.
Mode...: Timed
Segment: 1
Type...:>Power Level
Power..: 0.0 KW Time: 00:00:00
The default position of the cursor is next to Program. Press the Increase
or Decrease
button.
Use the Cursor
button to move the cursor to the desired selection, and press the Increase
or Decrease
button to
change the value to the desired setting.
Possible selections Timed:
Segment: 1 − 10
Type: Power Level, Slope, End
Power: 0.0 − 35
Time: 00:00:00 − 99:59:59 or Extended
7-5-4.
Manual Control
Manual control allows programming of a specific power level for a specific period of time. When this process is selected, the following screen appears
on the display:
Mode....: Manual Power..: 0.0 KW
Command.: 0.0 KW Current: 0 A
Run Time: 00:03:00 Voltage: 0 V
Frequency: 4.5 KHz
Manual Program Screen