Complete Parts List available at www.MillerWelds.com
Complete Parts List available at www.MillerWelds.com
OM-4421 Page 30
5-10. Connecting To Remote 14 Receptacle RC14 On CC/CV Models
Ref. 803 602
OR
Socket*
Socket Information
24 VOLTS AC
A
24 volts AC. Protected by sup-
plementary protector CB5.
B
Contact closure to A completes
24 volt AC contactor control
circuit.
REMOTE
OUTPUT
CONTROL
C
Output to remote c10
volts DC in MIG or Stick mode;
0 to +10 volts DC in TIG mode.
D
Remote control circuit common.
E
DC input command signal: 0 to
+10 volts from min. to max. of
remote control with Voltage/
Amperage Adjust control at
max.
115 VOLTS AC
I
115 volts, 10 amperes, 60 Hz
AC. Protected by supplementa-
ry protector CB6.
J
Contact closure to I completes
115 volt AC contactor control
circuit.
GND
K
Chassis common.
NEUTRAL
G
Circuit common for 24 and 115
volt AC circuit.
*The remaining sockets are not used.