Millennia
Millennia Media, Inc.
4600 Missouri Flat Road
Placerville, CA 95667
(530) 647-0750
Fax (530) 647-9921
Music
& Media Systems
HV-32P User Guide
revised 091614
Gain is a continuously variable gain
control. It has a high gain jump near full
clockwise for low level signals.
Signal LEDs indicate signal level at
-30dBu (green), +8dBu (yellow) and
+18dBu (red).
Ribbon-Dyn Mic DC couples the mic to
the gain stage and also provides an
additional 10dB of gain. Use with any
Ribbon or Dynamic mic (like an SM-57).
A mic requiring phantom power will not
work in this mode.
Pad – Attenuates the input signal after
the gain stage by about 14dB.
Phantom Power – turns the +48V
phantom power supply on.
Avoid connecting or disconnecting
mics with the +48V on (hot
patching). This can damage the
mic, preamp and make some very
loud pops that can damage your
monitoring system and ears.
External Power Supply – The HV-35P is
powered by a 12V DC, 2 amp, universal
voltage (100 to 240 VAC) line lump power
supply provided with the unit.
It can also be powered by battery packs
that produce between 12 and 15 VDC.
A 2,000 mAh NiMH 10 cell battery pack
will power the unit for more than 3hrs.
FCC Notice Information for the User
This equipment has been tested and found
to comply with the limits for a Class A digital
device, pursuant to part 15 of the FCC
Rules. These limits are designed to provide
reasonable protection against harmful
interference when the equipment is
operated in a commercial environment. This
equipment generates, uses, and can radiate
radio frequency energy and, if not installed
and used in accordance with this instruction
manual, may cause harmful interference to
radio communications. Operation of this
equipment in a residential area is likely to
cause harmful interference in which case the
user will be required to correct the
interference at his or her own expense.
Water, Moisture, and Spillage – Do not
attempt to use the HV32P in, near, or
around water or in unusually moist
environments, such as near a sink or
swimming pool. Prevent liquids or any other
materials or objects from spilling or falling
into the HV32P unit.
Grounding – For your safety, it is
extremely important that the grounding pin
of the 3-wire power cable (included with
110 Volt units) be inserted into a grounding
type 3-pin power outlet. If you are unable to
insert the plug into an existing outlet,
contact an electrician to install a properly
grounded 3-pin power outlet, preferably
that with OFI / CFI protection, if available.