22
For decoder examples please find files on
https://github.com/Milesight-IoT/SensorDecoders
.
5.1 Basic Information
EM300 series sensors report basic information of sensor whenever joining the network.
Example:
5.2 Sensor Data
EM300 series sensors report sensor data according to reporting interval (10min by default).
Battery level is reported every 6 hours.
Channel
Type
Description
ff
01(Protocol Version)
01=>V1
09 (Hardware Version) 01 40 => V1.4
0a(Software Version)
01 14 => V1.14
0f(Device Type)
00: Class A, 01: Class B, 02: Class C
16(Device SN)
16 digits
ff 09 01 00 ff 0a 01 02 ff 0f 00
Channel
Type
Value
Channel
Type
Value
ff
09
(Hardware
version)
0100 (V1.0)
ff
0a
(Software
version)
0102(V1.2)
Channel
Type
Value
ff
0f
(Device Type)
00
(Class A)
Channel
Type
Description
01
75(Battery Level)
UINT8, Unit: %
03
67 (Temperature)
INT16, Unit: °C
04
68(Humidity)
INT8, Unit: %
05
00(Water Leakage
Status)
00: Not water leaked
01: Water is leaked
06
00(Magnet Status)
00: Magnet switch close
01: Magnet switch open
05
c8(Counter)
4 bytes, unsigned
05
00(Digital)
00: low
01: high