Acquisition Control
MIKROTRON GmbH
5
‐
5
TriggerSource
This feature defines the source of the trigger signal.
TriggerSoftware
This feature generates an internal trigger.
Tip:
When using Trigger
‐
Software, the exposure time
of the next frame cannot be
defined by TriggerWidth of
the feature ExposureMode.
Instead, it has to be defined
by the feature Exposure
‐
Time.
Access
read / write
Type
enumeration
In
Line0
Line1
Software
CXPTrigger
CXP cameras with DIN connector offer one trig
‐
ger input with two physical lines via the 12 pin
Hirose connector (see page 3
7); the trigger sig
‐
nal can either be sent via line 0 or line 1
CXP cameras with DIN connector offer one trig
‐
ger input with two lines via the 12 pin Hirose
connector; the trigger signal can either be sent
via line 0 or line 1
if TriggerSoftware is set, the trigger will be gener
‐
ated by the software using the feature Trigger
‐
Software; no external (hardware) trigger signal is
needed
if CXPTrigger is set, the camera will wait for an
external trigger signal from the frame grabber
before acquiring another frame; exposure time
for the next image is the time defined in the fea
‐
ture ExposureTime
Out
The active source is available at OUT0 of the connected camera.
Remark
Only one trigger source can be active.
Access
write
Type
command
In
0x00000001
Out
—
Remark
In order to generate a software trigger signal, “Software” has to
be set in TriggerSource.
Summary of Contents for EoSens CAMMC1186
Page 1: ...EoSens 1 1CXP Camera Reference Guide V1 2...
Page 74: ...CHAPTER 11 Custom Features The chapter informs about the connected device on page 11 3...
Page 87: ...APPENDIX A Technical Data...
Page 89: ...APPENDIX B Spectral Response...
Page 91: ...APPENDIX C Bayer Pattern...
Page 94: ...APPENDIX D Camera Dimensions...
Page 95: ...Camera Dimensions MIKROTRON GmbH D 2 MC1186 and 1187 Rear View...