4CXP Camera
Manufacturer-specific Addresses
page 34 of 70
MIKROTRON GmbH
ConnectionConfig
This register holds a valid combination of the device link speed and number of active down
connections. Writing into this register sets the connection speeds on the specified connections.
Access
read / write
Type:
enumeration
In:
connection configuration example (read the electronically readable manual for further
information):
Enumeration
Description
CONNECTION4SPEED1250
four connections of 1.250 Gbps per connection
CONNECTION4SPEED2500
four connections of 2.500 Gbps per connection
CONNECTION4SPEED3125
four connections of 3.125 Gbps per connection
CONNECTION4SPEED5000
four connections of 5.000 Gbps per connection
CONNECTION4SPEED6250
four connections of 6.250 Gbps per connection
Out:
connection configuration
ConnectionConfigDefault
This register provides the value of the ConnectionConfig register that allows the Device to operate in
default mode. This feature is used to start the camera with the default configuration that is stored in
the custom profiles.
Access
read
Type:
unsigned integer
In:
Out:
0x00000000
Remark:
It allows a simple host (e.g. a basic “closed system” format converter) to automatically
set the correct bit rate and obtain images from a device
TestMode
Writing the value 0x00000001 into this register enables a test packet transmission from the camera
to the host.
Access
read / write
Type:
integer
In:
Value
Description
0x00000000
normal operation
0x00000001
sending test packets to host
Out:
same as above
Remark:
A connection reset sets the value to 0x00000000.
If the value is changed from
0x00000001 to 0x00000000, the device will complete the packet of 1024 test words
currently being transmitted.