background image

Wireless Wire Cube

Wireless Wire Cube

 (CubeG-5ac60adpair)

Safety Warnings

Before you work on any equipment, be aware of the hazards involved with electrical circuitry, and be familiar with standard practices for preventing 

accidents.

Ultimate disposal of this product should be handled according to all national laws and regulations.

The Installation of the equipment must comply with local and national electrical codes.

This unit is intended to be installed in the rackmount. Please read the mounting instructions carefully before beginning installation. Failure to use the 

correct hardware or to follow the correct procedures could result in a hazardous situation to people and damage to the system.

This product is intended to be installed indoors. Keep this product away from water, fire, humidity or hot environments.

Use only the power supply and accessories approved by the manufacturer, and which can be found in the original packaging of this product.

Read the installation instructions before connecting the system to the power source.

We cannot guarantee that no accidents or damage will occur due to the improper use of the device. Please use this product with care and operate at your 

own risk!

In the case of device failure, please disconnect it from power. The fastest way to do so is by unplugging the power plug from the power outlet.

It is the customer's responsibility to follow local country regulations, including operation within legal frequency channels, output power, cabling 

requirements, and Dynamic Frequency Selection (DFS) requirements. All Mikrotik radio devices must be professionally installed.

This is a class A device. In a domestic environment, this product might cause radio interference in which case the user might be required to take adequate 

measures.

Exposure to Radio Frequency Radiation: This MikroTik equipment complies with the FCC, IC, and European Union radiation exposure limits set forth for an 

uncontrolled environment. This MikroTik device should be installed and operated no closer than 21 centimeters from your body, occupational user, or the 

general public.

Quickstart

Connect the device to the included PoE injector with Ethernet cable;

Connect the PoE injector into the PC or to the network switch;

Connect the power adapter to the PoE injector;

Download WinBox configuration tool

;

 

https://mt.lv/winbox

Open WinBox and connect to the device;

Default IP: 192.168.88.2/192.168.88.3, user name: 

admin, please find the password on the sticker;

Download the latest RouterOS software from

;

 

https://mikrotik.com/download

Choose ARM packages, and save them to your PC;

Open WinBox and upload downloaded packages, drag and drop into any windows;

Restart the device;

Connect again and select your Region in the Wireless menu, W60G tab, and in 

menu set your Country, to apply country regulation 

QuickSet 

settings.

If device RX blocking condition has happened device will restore its signal after a few seconds.

It is the customer's responsibility to follow local country regulations, including operation within legal frequency channels, output power, cabling 

requirements, and Dynamic Frequency Selection (DFS) requirements. All Mikrotik radio devices must be professionally installed.

 

 

Note. The information contained here is subject to change. Please visit the product page on

www.mikrotik.com

for the most up to date version of 

this document.

Summary of Contents for CubeG-5ac60adpair

Page 1: ... devices must be professionally installed This is a class A device In a domestic environment this product might cause radio interference in which case the user might be required to take adequate measures Exposure to Radio Frequency Radiation This MikroTik equipment complies with the FCC IC and European Union radiation exposure limits set forth for an uncontrolled environment This MikroTik device s...

Page 2: ...g here to get yourself accustomed to the possibilities In case IP connection is not available the Winbox tool can be used to connect to the MAC address https mt lv help https mt lv winbox of the device from the LAN side all access is blocked from the Internet port by default For recovery purposes it is possible to boot the device from the network see Reset button If the device loses connection wai...

Page 3: ...re it will be mounted Slide the loose end of the mounting ring back to its closing latch and use the screwdriver to tighten it The IP rating scale for this device is IP54 When mounting outdoors please ensure that any cable openings are directed downwards We recommend using the POE injector and proper grounding with Cat6 shielded cable When using and installing this device please pay attention to M...

Page 4: ...to the PoE adapter Connect the power cord to the adapter and then plug the power cord into a power outlet Extension Slots and Ports 10 100 Ethernet port Integrated 5 GHz 802 11a n ac interface with built in antenna WiGig chipset QCA6335 Reset button The routerBOOT reset button has the following functions Press the button and apply the power then Release the button when green LED starts flashing to...

Page 5: ...t expressly approved by the party responsible for compliance could void the user s authority to operate this FCC Caution equipment This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Th...

Page 6: ... RSS 210 Annex J 1 IMPORTANT NOTE IC Radiation Exposure Statement This equipment complies with IC RSS 102 radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with a minimum distance 21cm between the radiator your body Cet équipement est conforme aux limites d exposition aux rayonnements IC établies pour un environnement non contrôlé C...

Page 7: ...ikrotīkls SIA declares that the radio equipment type CubeG 5ac60adpair is in compliance with Directive 2014 53 EU The full text of the EU declaration of conformity is available at the following internet address https mikrotik com products WiGig Operational channels Maximum output power Betriebskanäle maximale Ausgangsleistung Canaux opérationnels puissance de sortie maximale Canali operativi massi...

Page 8: ...Frequenza operativa massima potenza di uscita Frecuencia de funcionamiento potencia de salida máxima Рабочая частота максимальная выходная мощность ...

Reviews: