background image

1. Introduction

SHT1x  Click  is  an  accessory  board  in 

mikroBus

  form  factor.  It  includes  a 

digital  humidity  and  temperature  sensor 

SHT11

. A unique capacitive sensor element 

is used to measure relative humidity while 
the  temperature  is  measured  by  a  band-
gap sensor. Serial  I

2

C interface and factory 

calibration,  allow  easy  and  fast  system 
integration. Board is set to use 3.3V power 
supply  by  default.  Solder 

PWR  SEL

  SMD 

jumper  to  5V  position  if  used  with  5V 
systems.

Once  you  have  soldered  the  headers  your 
board  is  ready  to  be  placed  into  desired 
mikroBUS™  socket.  Make  sure  to  align  the 
cut  in  the  lower-right  part  of  the  board 
with the markings on the silkscreen at the 
mikroBUS™ socket. If all the pins are aligned 

correctly,  push  the  board  all  the  way 

into the socket.

3. Plugging the board in

2

3

2. Soldering the headers

1

4. Getting The Data

Communication  with  the  SHT11  sensor  is 
done  using  I

2

C  interface.  Temperature  can 

be  represented  in  12-bit  or  14-bit  format 
in operating range from -40 to +100°C with 
accuracy  of 

!

0.5°C  at  room  temperature. 

Humidity  can  be  represented  in  8-bit  or 
12-bit resolution with 

!

3% accuracy.

Turn  the  board  upward  again.  Make  sure 
to  align  the  headers  so  that  they  are 
perpendicular to the board, then solder the 
pins carefully.

Turn  the  board  upside  down,  so  that 
bottom side is facing you upwards. Place 
shorter  parts  of  the  header  pins  in  the 
both soldering pad locations.

SHT1x 

click

Front and back side appearance 

of the SHT1x click Board

Before using your click board, make sure 
to solder the provided 1x8 male headers 
to both sides of the board. Two 1x8 male 
headers  are  included  with  the  board  in 
the package.

click

BOARD

www.mikroe.com

SHT11 click Manual

ver. 1.00

0 100000 020128

Reviews: