7.2
Regulatory elements
TK-24 18/24/27 kW
TK-24 18kW
- Main switcher
– Turning ON device and possibly to
turn on external circulation pump.
1
- Switcher 1
– Turning on heater
I
with power of 6 kW
Via working and room thermostat,
(Signalling diode in it indicates heater work).
2
- Switcher 2
– Turning on heater
II
with power of 6 kW
Via working and room thermostat,
(Signalling diode in it indicates heater work).
3
– Switcher 3 – Turning on heater
III
with power of 6 kW
Via working and room thermostat,
(Signalling diode in it indicates heater work).
e
– Signal bulb (between switcher and switcher
1
)
Signalling economic condition
– boiler works with
Reduced power.
4
– Working thermostat - for temperature selection in boiler.
Thermostat is three-grade, turns on/off heaters one by
one each 5°C. As such it eliminates shocks to electric
network and provides more accurate achievement and
maintenance of work temperature. Recommendation:
adjust boiler temperature within economic range of
50°C - 70°C
TK-24 24/27 kW
- Main switcher
– Turning ON device and possibility to
turn on external circulation pump.
1- Switcher 1
– Turning on heater
I
with power of 8/9 kW
Via working and room thermostat
(Signalling diode in it indicates heater work).
2
2-Switcher 2
– Turning on heater
II
with power of 8/9 kW
Via working and room thermostat
(Signalling diode in it indicates heater work).
3
3-Switcher 3
– Turning on heater
III
with power of 8/9 kW
Via working and room thermostat,
(Signalling diode in it indicates heater work).
e
– Signalling diode (between switch and switch
1
)
Signalling economic condition
– boiler works with
reduced power.
4
– Working thermostat - for temperature selection in
boiler. Thermostat is three-grade, turns on/off heaters
one by one each 5°C. As such it eliminates shocks to
electric network and provides more accurate
achievement and maintenance of work temperature.
Recommendation: adjust boiler temperature within
economic range of 50°C - 70°C
IZBOR
Power selection
TK-24;
18/24/27kW
by combination of
control panel switches
Work instruction for
TK-24 18/24/27kW