background image

For technical questions: 
Phone: 585-637-3760 
Email: [email protected] or visit www.mijet.com 
 
For sales questions contact: 
Jeff Gagnon 
VP of Sales 
MiJET Division of Custom Service Solutions, Inc. 
Phone: 585-472-6294 
Fax: 207-345-3171  
Email: [email protected] 

 

MiJET™ 
www.mijet.com 

 

U S E R   G U I D E  

Product of: 

EASY TO GET STARTED 

 

Ready to use with one existing air line. 

 

All-in-one workstation powered by air 

U S E R   G U I D E  

 

M I J E T  

WA S H S TAT I O N  

Date: 

Summary of Contents for WASHSTATION

Page 1: ...contact Jeff Gagnon VP of Sales MiJET Division of Custom Service Solutions Inc Phone 585 472 6294 Fax 207 345 3171 Email jeff mijet com MiJET www mijet com USER GUIDE Product of EASY TO GET STARTED R...

Page 2: ...thout any re strictions such as a quick connect It is also recommended to utilize a 3 8 diameter air hose from the main line to supply the MiJET A smaller diameter coiled air line or a line that is to...

Page 3: ...rts Basket Fine Mesh for 12 dia MiJET angled top workstation and wash station 13 5 x 7 25 x 9 75 13 057 13 058 High Flow Quick Disconnect Body High Flow Quick Disconnect Plug Page 3 U S E R G U I D E...

Page 4: ...tool oil refer to the maintenance steps on page 6 Q The suction is reduced from when the unit was brand new A Try adding air tool oil refer to the maintenance steps on page 6 B Check filter and if oi...

Page 5: ...ews with the 7 32 Allen key Hold the black plastic handle while tightening to ensure the correct handle orientation of the T Handle 6 Repeat the same procedure for the second screw on the opposite sid...

Page 6: ...th the MiJET can reduce the MiJET air nozzle pressure by 30 If quick connects are needed use high flow quick connect such as MiJET accessory 13 057 Coupler body and 13 058 Coupler plug See accessory p...

Page 7: ...e 17b Figure 17a Figure 17b Page 7 U S E R G U I D E 1 Remove MiJET from pallet 2 Attach the Loc Line Faucet as shown in Figures 1a and 1b 3 Add desired amount of aqueous or oil based cleaning solutio...

Page 8: ...air supply before removing container Filter as necessary per company policy Figure 3 Figure 4 5 Air supply should be capable of 35 CFM at 90 PSI and be filtered MiJET can be installed down the line f...

Page 9: ...will build up in both the Dip Container and the fluid filter if not properly maintained Figure 12 Figure 13 Cleaning Procedure Page 9 U S E R G U I D E Using the Faucet 1 Utilize the faucet by turnin...

Page 10: ...Figure 9 Page 10 U S E R G U I D E Removing MiJET from Table 8 With one hand on the top of the unit and one hand one the bottom of the unit twist to unlatch from the hook 9 Lower the unit down and ou...

Reviews: