50113718 A
QUICKGUIDE SIGMA
2
ADVANCED
UK
Process
1.0 mm
1.5 mm
2.0 mm
3.0 mm
Induc-
tance
Mate-
rial
Wire
Gas
S
(m/min)
U0
(V)
S
(m/min)
U0
(V)
S
(m/min)
U0
(V)
S
(m/min)
U0
(V)
Fe
0.8
CO
2
2.5
19.0
4.5
19.5
7.0
21.0
11.0
27.0
0
Fe
1.0
CO
2
2.0
18.0
2.5
19.0
3.0
20.0
4.5
21.0
0
Fe
1.2
CO
2
1.0
18.0
2.0
20.0
2.5
21.0
3.5
22.0
0
Fe
0.8
ArCO
2
3.0
16.0
6.0
18.0
7.5
19.5
11.0
20.0
1
Fe
1.0
ArCO
2
2.0
15.0
3.0
16.0
4.0
17.0
6.0
19.0
2
Fe
1.2
ArCO
2
1.5
16.5
2.5
17.5
3.5
18.0
4.5
20.5
0
Fe
1.6
ArCO
2
1.0
17.0
2.0
18.0
2.5
18.5
3
CrNi
1.0
ArCO
2
3.0
15.0
4.0
16.0
6.0
17.0
8.5
20.0
1
CrNi
1.2
ArCO
2
2.0
15.0
3.0
16.0
3.5
16.5
6.0
18.0
2
AI
1.0
Ar
4.0
14.5
6.0
15.0
7.5
16.0
9.0
19.0
0
AI
1.2
Ar
3.5
13.0
5.0
15.0
8.0
16.0
9.0
17.0
0
Process
4.0 mm
6.0 mm
10.0 mm
Induc-
tance
Mate-
rial
Wire
Gas
S
(m/min)
U0
(V)
S
(m/min)
U0
(V)
S
(m/min)
U0
(V)
Fe
0.8
CO
2
13.0
29.0
18.0
30.0
24.0
37.0
0
Fe
1.0
CO
2
6.0
22.5
9.0
24.5
14.0
32.0
0
Fe
1.2
CO
2
4.5
23.0
7.5
28.5
11.0
36.0
0
Fe
0.8
ArCO
2
14.0
26.0
18.0
31.0
24.0
33.0
1
Fe
1.0
ArCO
2
8.0
20.0
11.5
26.5
16.0
30.0
2
Fe
1.2
ArCO
2
5.5
20.5
8.0
29.0
10.0
32.0
0
Fe
1.6
ArCO
2
3.0
19.5
4.0
22.0
5.5
29.0
3
FeFlux
1.2
ArCO
2
6.0
21.0
8.0
25.0
11.0
28.0
0
CrNi
1.0
ArCO
2
9.0
25.0
10.0
27.0
1
CrNi
1.2
ArCO
2
8.0
24.0
10.0
24.0
12.0
31.0
2
AI
1.0
Ar
11.0
22.0
13.0
25.0
15.0
27.0
0
AI
1.2
Ar
10.0
18.0
13.0
23.0
15.0
26.0
0
Welding table for SIGMA 300/400/500 (set value)
Table 1
Setting the welding process
Press and hold (11A) to open for setting the welding process. Choose parameter by turn-
ing (10). Set the chosen value by turning (11). To close this function, press (11A) briefly.
MIG/MAG parameters
Actual welding current (A)
t
A
Figure 1
F32
F31
F39
F37
F38
A
MMA (electrode) parameters
When the MMA welding program is chosen, the operator is
allowed access to the following parameters only.
t
Short circuit
Set welding
current (A)
F13
F12
t
F11
%
%
F11
Hotstart
(25%)
F12
Hotstart time (0,5 sec.)
F13
Arc force
(25%)
F31
Pre-gas
(0,2 sec.)
F32
Softstart
(1,0 m/min.)
F37
Burn-Back (5
(1-15))
F38
Post-gas (3,0
sec.)
F39
Spot time (0,0 sec.)