Migatronic PI 200 DC Instruction Manual Download Page 10

 

22

The following diagram display all parameters and options of menu. 

 

 

 

 
 
 
 

Exit from the USER menu 
 

Open/Close the gas valve in order to purge 
the torch, check the gas bottle and pressure 

reducer. Press “A to Open/Close the gas. Exiting the 
USER menu will close the gas anyway. 

 
Submenu containing different options: 
 

Exit from the submenu (go back to 
main menu) 

 

Programs LOCK 
Protection of programs P3 to P10 

for all procediment against unintentional 
change of: 

  welding currents, slopes, timing 

 Trigger 

selection 

2T/4T 

  Current reference EXT/Internal 

 Pulsations 

 
It is still possible to select different 
programs and welding procediment. 
Programs P1 and P2 are unlocked, 
permitting full control of relative 
parameters. 
When pressing locked key pads or rotating 
the encoder for locked parameters, the 
display will flash “PG.L.” to remember the 
active protection. 
0 = unlocked (default setting)  
1 = locked 
 

Panel LOCK  
Complete lock of box. All keypads 

and Encoder are disabled. 
When pressing locked key pads or rotating 
the encoder, the display will flash “PA.L.” to 
remember the active protection. 
0 = unlocked (default setting)   
1 = locked 
 

4-times option for torch trigger  
Permit to define 4 different ways to 

control the torch trigger when the machine is 
set as 4Times stroke (Lift or HF). Mode 3 is 
called 4T-REPEAT and permits to keep the 
arc active also at the end of slope down for 
an easier restart of sequence. In Mode 3 the 
function “Second current level” is disabled.

 

For detailed description of different 
behaviours see the following diagrams. 
Select a value in the range 0...3 (1=default 
setting). 

 

 

 

 

Dynamic Oxide Control  
(for AC welding). 

0 = disabled  
1 = enabled (default setting) 

 
 
All above settings are not modified via Reset. 

 

Summary of Contents for PI 200 DC

Page 1: ...ing Instruction manual Betriebsanleitung Manuel d instruction Manuale d istruzione Bruksanvisning Käyttöohje Manual de instrucciones Gebruikershandleiding Manual de instruções Podręcznik obsługi Valid from 2012 week 09 50113201 R ...

Page 2: ...by declare that our machine as stated below Type PI 200 250 DC HP As of Week 44 2005 conforms to directives 2006 95 EC and 2004 108 EC European Standards EN IEC60974 1 EN IEC60974 2 EN IEC60974 3 EN IEC60974 10 Class A Issued in Fjerritslev on 1st November 2005 Peter Roed Managing director ...

Page 3: ...wing Electricity The welding equipment must be installed according to safety regulations and by a properly trained and qualified person The machine must be connected to earth through the mains cable Make sure that the welding equipment is correctly maintained In the case of damaged cables or insulation work must be stopped immediately in order to carry out repairs Repairs and maintenance of the eq...

Page 4: ...s of the breaker 3 on the rear of the machine Lifting instructions The lifting point must be used as shown in the following drawing The machine must not be lifted with a mounted gas bottle Configuration MIGATRONIC disclaims all responsibility for damaged cables and other damages related to welding with undersized welding torches and welding cables measured by welding specifications e g in relation...

Page 5: ... MMA The electrode holder and return current cable are connected to plus tap 5 and minus tap 4 Observe the instructions from the electrode supplier when selecting polarity Connection of foot control Foot control is connected to the 7 poled plug 7 or through the 8 poled plug 15 depending on the foot control type Connection of remote control PI machines equipped with 8 pole control interface 15 can ...

Page 6: ...eep pressed the knob after 3 sec the display will start flashing to indicate the current program has been restored to Factory settings The latest used program setting in the relevant program group MMA DC and TIG DC will be shown when the program key pad is selected Welding current The key pad can be used to display the welding current Adjustable from 5A to 200A or 250A depending on the machine mod...

Page 7: ...achine enters a slope down stage During this stage current is reduced from welding current to Final Amp over a period of time called the slope down time and variable 0 20 sec in steps of 0 1 sec Final Amp A The slope down stage is completed when the current level has fallen to the value stated in the Final Amp parameter In 4 times it is possible to continue in Final Amp mode until the trigger is r...

Page 8: ...mp Arc power can be adjusted between 0 and 100 of the welding current setting E g If the welding current is set to 40A and arc power to 50 the additional current is 20 A equals 60 A when doing arc power If the arc power is set to 100 the additional current is 40 A equals 80 A when doing arc power Torch adjustment remote control 7 poled plug The regulation of welding current is made by means of the...

Page 9: ...ti freeze control The anti freeze control reduces the current when the electrodes stick to the weld piece This makes it easier to break off the electrode and welding can continue Reset It is possible to recall all factory standard parameters In this case all programs in the machine will be reset to the following value MMA current 80A TIG Current 80A TIG Spot Current 80A Pre flow 0 0 sec Post flow ...

Page 10: ...ting the encoder for locked parameters the display will flash PG L to remember the active protection 0 unlocked default setting 1 locked Panel LOCK Complete lock of box All keypads and Encoder are disabled When pressing locked key pads or rotating the encoder the display will flash PA L to remember the active protection 0 unlocked default setting 1 locked 4 times option for torch trigger Permit to...

Page 11: ...0 01 10 secs Pause time TIG MMA 0 01 10 secs Base Amp TIG MMA 10 90 Second current Bilevel TIG 10 200 TIG ignition TIG HF LIFTIG Triggerfunction TIG 2 4 stroke 1 S The machine meets the standards which are demanded of machines working in areas where there is an increased risk of electric shock 2 Equipment marked IP23 is designed for indoor and outdoor applications MAINTENANCE The machine requires ...

Page 12: ...t made the standard warranty period is twelve months for new welding machines as from the date of invoicing to end user The original invoice is documentation for the warranty period Migatronic provides warranty according to the warranty conditions in force through remedying defects in the welding machines that can be proved to be caused by improper materials or workmanship in the warranty period A...