Migatronic Green Pointer X2 User Manual Download Page 8

8

Connection and start-up

Application

Green Pointer X2 features:

  Grinding of oxidated or pure tungsten electrodes

  Grinding electrodes with diameters from 1.0 to 4.0 mm

  Variable angle adjustment from 15° to 180°

  Minimizing grinding costs

  Grinding electrodes down to 15 mm length

  Special electrode clamp for electrodes shorter than 

15 mm 

  Integrated filter to remove the grinding dust

  Suitable for site welding operations

  For exact longitudinal grinding

Technical data &  
contents of standard package

Motorydelse: 

850 Watt

Power: 230V/50Hz
Rpm: 

Adjustable between 14000 min

-1

 and  

 

24000 min

-1

Weight: 

2.5 kg

Filter: 

Inhalation filter

Diamond wheel:  Ø 40 mm

Storage case:
•  Green Pointer X2 containing:
  -  Motor Type WAG40
  -  Grinding head with filter housing and filter
  -  Diamond wheel  Ø 40 mm
  -  Electrode holder
  -  Electrode clamps 1.6; 2.4; 3.2 mm

• 

Tools:

  -  Allen key 8 mm
  -  Allen key 4 mm
  -  Spanner 13/17 mm
  -  Spanner 13/14 mm

•  Plastic bag to remove the filter

Before use

Note:   Ensure that the grinding head (2) is centred and tightly 

fixed with the allen screw (15) to the motor

How to select grinding position

With the Green Pointer X2 it is possible to select 3 different 
grinding positions.
-  Unscrew the knurled wheel (22).
-  Lift the eccentric plate (20) and turn through 90° to the next 

position, place the eccentric plate back in the slide of the 
angle adjustment.

-  Tighten the knurled wheel (22).

Eccentric plate to select the grinding position

Selection of electrode diameter

There are 3 different electrode clamps (1.6, 2.4, 3.2 mm) 
supplied with the machine. Unscrew the electrode clamp from 
the electrode holder and replace with the required size.

Selection of angle

-  Loosen slightly the knurled wheel (22).
-  Place the degree sign of the guide (20) at the selected 

angle.

-  Tighten the knurled screw (22).

Note:
-  15° is the smallest included angle of the electrode, that can 

be ground.

-  180° position makes a flat on the electrode point. 
-  (1 step = 5°)

s

s

s

1

(left mark)

2

(centre mark)

3

(right mark)

Inside grinding

position

Centre grinding

position

Outside grinding

position

Summary of Contents for Green Pointer X2

Page 1: ...50119012 D Valid from 2021 week 06 GREEN POINTER X2 Brugsvejledning User guide Betriebsanleitung Guide de l utilisateur Podr cznik u ytkownika...

Page 2: ...9690 Fjerritslev Denmark hereby declare that our machine as stated below Type Green Pointer X2 conforms to directives 2006 42 EU 2014 35 EU 2014 30 EU 2011 65 EU 2012 19 EU European standards 12100 20...

Page 3: ...Start kun maskinen mens elektrodeholderen sidder i indf ringskanalen Fjern f rst elektrodeholderen efter at maskinen er standset Ret eller korriger eventuelle mangler Reparation af de elektriske dele...

Page 4: ...gle 13 17 mm N gle 13 14 mm Plastikpose til brugt filter Inden opstart Bem rk Slibehovedet 2 skal sidde fast centreret ind til brystet af motoren V r opm rksom p at sp ndskruen 15 er fastsp ndt Valg a...

Page 5: ...for stort tryk med elektrode holderen idet dette betyder en for get nedslidning af slibeskiven Inden maskinen startes skal elektrodeholderen altid befinde sig i f ringskanalen og den m ikke fjernes f...

Page 6: ...6...

Page 7: ...in the grinding chamber Do not remove the electrode holder before the motor has come to a complete stop Correct and adjust possible defects Repairs and maintenance must only be carried out by authoris...

Page 8: ...to remove the filter Before use Note Ensure that the grinding head 2 is centred and tightly fixed with the allen screw 15 to the motor How to select grinding position With the Green Pointer X2 it is...

Page 9: ...der before the stop 14 has been reached Remember to put the electrode holder into the grinding chamber before you start the machine and to keep it there until the motor has stopped Otherwise grinding...

Page 10: ...10...

Page 11: ...reiben Filterkassette nach Betriebsanleitung wechseln Ger t nur betreiben wenn sich der Elektrodenhalter im Zuf hrungskanal befindet den Elektrodenhalter nach dem Anschleifen erst dann entfernen wenn...

Page 12: ...ssel 13 14 mm Entsorgungsbeutel f r Einwegfilter Vorbereitende Arbeiten Achtung Der Schleifkopf 2 muss mittig und bis zum Anschlag an das Motorgeh use fest montiert sein Die Schleifkopfspannschraube 1...

Page 13: ...in zu starker Druck der Elektrode auf die Schleifscheibe sollte vermieden werden bevor der Anschlag 14 erreicht ist Vor dem Einschalten des Ger tes muss sich immer der Elektrodenhalter 5 im Zuf hrungs...

Page 14: ...14...

Page 15: ...ambre d aff tage Ne pas retirer le porte lectrode avant l arr t complet du moteur Rectifier ou corriger les manquants ventuels Seul le personnel autoris est habilit effectuer les r parations et activi...

Page 16: ...m Sacs en plastique pour filtres usag s Avant la mise en marche A noter v rifiez que la t te d aff tage 2 est centr e et fermement fix e au moteur avec la vis crou six pans 15 Comment s lectionner la...

Page 17: ...ter n appuyez pas trop fort sur le porte lectrode si la but e 14 n a pas t atteinte N oubliez pas de mettre le porte lectrode dans la chambre d aff tage avant de d marrer la machine et ne l enlevez pa...

Page 18: ...18...

Page 19: ...czaj tylko wtedy gdy uchwyt elektrody znajduje si w komorze ostrz cej Nie wyjmuj uchwytu elektrody zanim silnik nie zatrzyma si ca kowicie Naprawy i konserwacje wykonywa mog tylko upowa nieni pracowni...

Page 20: ...busowy 8 mm Klucz imbusowy 4 mm Klucz maszynowy 13 17 mm Klucz maszynowy 13 14 mm Worek plastikowy do usuwania filtra Przed u yciem Uwaga Upewnij si e g owica ostrz ca 2 jest wypo rodkowana i mocno do...

Page 21: ...osi gnie ogranicznika 14 Pami taj aby umie ci uchwyt elektrody w komorze ostrz cej przed uruchomieniem urz dzenia oraz pozostawi go w rodku do czasu zatrzymania si silnika W przeciwnym razie py powst...

Page 22: ...rienr 15800 og opefter On Off switch for 650W motor On Off switch for 850W motor Old type On Off switch for 850W motor New type serial no 15800 and up Ein Ausschalter 650W motor Ein Ausschalter 850W m...

Page 23: ...amp 2 4mm Spannzange 2 4mm Pince porte lectrode 2 4mm Zacisk elektrody 2 4mm 1 82036176 16 5 Klemtang 3 2mm Electrode clamp 3 2mm Spannzange 3 2mm Pince porte lectrode 3 2mm Zacisk elektrody 3 2mm 1 8...

Page 24: ...4 Cl SW13 SW14 Klucz maszynowy SW13 SW14 1 42 Unbracon gle 2 mm Allen key 2 mm Inbusschl ssel 2 mm Cl hexagonale 2 mm Klucz imbusowy 8 mm 1 43 Unbracon gle 4 mm Allen key 4 mm Inbusschl ssel 4 mm Cl h...

Page 25: ......

Page 26: ...411 135 600 www migatronic cz Hungary MIGATRONIC KERESKEDELMI KFT Szent Mikl s u 17 a H 6000 Kecskem t Hungary Tel 36 76 505 969 www migatronic hu MIGATRONIC ASIA China SUZHOU MIGATRONIC WELDING TECHN...

Reviews: