en - Installation notes
*INSTALLATION*
29
Only connect the washing machine to the water supply with the
hoses supplied.
Cold water con-
nection
For the cold water connection one stopcock each with a
3/4" external thread is required. A connector (Y-piece) can be used if
required to connect 2 water inlet hoses with a ¾" screw thread to a
single stopcock with a 1" male thread.
Hot water con-
nection
To minimise energy consumption during operation with hot water,
the washing machine should be connected to a suitable hot water
ring circuit if present.
So-called “transmission pipes” (single pipes to hot water generators)
can result in cooling down of the water remaining in the pipes if not
in constant use. More energy would then be consumed to heat the
suds up again.
The temperature of the water intake must not exceed 70 °C on ma-
chines with electric heating (EL).
The machine must be connected to the water supply using the inlet
hoses provided.
If there is no hot water supply at the installation location for the wash-
ing machine, the inlet hose for hot water must also be connected to
the cold water supply. A Y-piece is required in this case. The cold wa-
ter consumption increases accordingly to account for the missing hot
water intake.
For functional and technical reasons it is not possible to operate
the machine exclusively with a hot water connection.
Even if a hot water connection is present, the washing machine
must be connected to a cold water intake.
Drain valve
In the case of washing machines with a drain valve, a motorised valve
is used to drain the machine. An HT DN 70 angle connector can be
used for draining the machine directly into the waste water system
(without a siphon) or into an on-site floor drain (with odour trap).
Thanks to an improved closing mechanism and a larger cross-sec-
tion, even the coarsest of soiling does not leave any deposits or
debris behind which could result in blockages. The drain valve can
also be operated manually to allow the suds container to be emptied
in the event of a power outage.
Summary of Contents for PWM 920 EL
Page 2: ...2 de 4 en 25 fr 45 es 67 ru 88 it 110 ...
Page 18: ...de Aufstellung INSTALLATION 18 Standard Maßangaben in Millimeter Standfuß ...
Page 19: ...de Aufstellung INSTALLATION 19 Sockel Maßangaben in Millimeter ...
Page 38: ...en Installation INSTALLATION 38 Standard Dimensions in mm Machine foot ...
Page 39: ...en Installation INSTALLATION 39 Plinth Dimensions in mm ...
Page 59: ...fr Installation INSTALLATION 59 Par défaut Dimensions en millimètres Pied ...
Page 60: ...fr Installation INSTALLATION 60 Socle Dimensions en millimètres ...
Page 81: ...es Emplazamiento INSTALLATION 81 Estándar Medidas en milímetros Base de apoyo ...
Page 82: ...es Emplazamiento INSTALLATION 82 Zócalo Medidas en milímetros ...
Page 103: ...ru Установка INSTALLATION 103 Стандарт Размеры в мм Ножка ...
Page 104: ...ru Установка INSTALLATION 104 Цоколь Размеры в мм ...
Page 124: ...it Posizionamento INSTALLATION 124 Standard Misure in millimetri Piedino ...
Page 125: ...it Posizionamento INSTALLATION 125 Base Misure in millimetri ...