Optional modules
40
Dispenser calibration
Dispenser calibration is used to measure the throughput of the indi-
vidual dispensing pumps.
To go directly to
Dispenser calibra-
tion when the ma-
chine is switched
off:
Press and hold multifunction button 2 and switch the machine on
with
“Power on”.
Dispenser calibration
Main menu
Dispenser pump 1
Dispenser pump 2
Options:
-
Dispensing pump
1
to
13
Select a dispensing pump.
When a dispensing pump is selected, the following will appear in the
display:
100 ml
Dispenser calibration
Dispenser pump 1
V:
P:
t:
s
No
0
0/1
Tip:
The dispensing quantity can be set from 0 to 9999 ml in 1 ml in-
crements.
Press the multifunction button
0/1
.
The dispensing hose will fill up.
Stop the process by pressing the
0/1
button.
Run the hose of the dispensing pump upwards into a measuring
vessel.
Hold the entire measuring vessel above the dispensing pump while
doing this.
Irritant detergents.
Skin and eye irritation.
Avoid contact with skin and eyes, wear protective clothing.
Return to the main menu by pressing the
“Back” button.
Dispenser calibration
Main menu
Dispenser pump 1
Dispenser pump 2
Select a dispensing pump.