Settings menu
82
DOS flow rate
A flow rate of 60 ml/min is set as
standard. The flow rate can be modified
between 10 and 150 ml/min in
increments of 5 ml/min.
Set the dosage according to the
detergent manufacturer's
recommendations.
Choose the required detergent or
flow rate quantities and confirm your
selection with the
OK
button.
Venting the dispensing system
The dispensing system will not
dispense reliably if there is air in the
system.
The dispensing system must be vented
if:
– The dispensing system is being used
for the first time
– The liquid detergent reservoir was not
refilled in time and the DOS system
was emptied
– The detergent canister was replaced
To ensure that the dispensing
system functions properly, prior to
venting make sure that the detergent
container is full enough and that the
dispensing lances are firmly attached
to the containers.
Select
Start venting
and press the
middle button to confirm.
The venting process will begin. The
remaining time appears in the display.
The “Pre-wash” program is offered
directly after the venting process is
finished. Start the program in order to
dilute and drain any cleaning agent that
escaped into the wash cabinet.
Temperature unit
The temperature can be displayed in
degrees Celsius or degrees Fahrenheit.
Select the setting you want and
confirm with
OK
.
High-temperature final rinse
For better drying, the final rinse
temperature can be increased for
individual programs. This function is not
available for all programs (see “Program
overview”).
Select the setting you want and
confirm with
OK
.