Supervisor level
74
Additional fan
External hardware is connected via the
Miele XCI box.
If an extra fan is connected, it must be
switched on at the same time as the
drive unit.
– Off
– On
Pressure sensor
External hardware is connected via the
Miele XCI box.
When using a shared exhaust air duct,
one tumble dryer may have to be
switched off or suppressed from the
outset if certain pressure levels have
built up in the ducting. Because the
pressure sensor is an external unit,
there is the option of reading in both a
logical normally open contact or a nor-
mally closed contact.
A message appears in the display while
the exhaust air flap is open.
– Off = Not active
–
NO contact
= Active
Responds to
high potential
–
NC contact
= Active
Responds to
low potential
Payment system
External hardware is connected via the
Miele XCI box.
Setting for payment systems
If you wish to change the settings after
the commissioning process, please
contact Miele Service.
You would like to connect a payment
system.
– No payment system
The next settings are skipped and ini-
tial commissioning can be com-
pleted.
– Programme operation
The machine is operated using a coin
box. The user purchases a wash pro-
gramme.
– Timed operation
The tumble dryer is coin-operated
using a time meter. The user pur-
chases a time-controlled programme.
– Timed operation with pulse counter
For payment systems where the us-
age time is increased each time a
coin is inserted.