Connection to the gas supply, or conversion from one
type of gas to another, should only be undertaken by an
approved and registered gas installer in strict accordance
with local and national safety and building regulations
(e.g. Gas Safe registered in the UK).
When converting to a different type of gas, the main burner
jets and the small burner jets have to be changed.
Jet table
Main jet
C
Small jet
C
Natural gas H
Small burner
Front medium burner
Back medium burner
Large burner
Wok burner
0.76
0.94
1.03
1.20
1.45
0.39
0.42
0.42
0.54
0.80
Liquid gas
Small burner
Front medium burner
Back medium burner
Large burner
Wok burner
0.52
0.66
0.72
0.81
0.97
0.23
0.36
0.36
0.42
0.54
The jet markings refer to 1/100 mm of the jet diameter.
Conversion to another type of gas