*INSTALLATION*

Building-in dimensions

Dimensions are given in mm.

Installation in a tall or base unit

When building the oven into a base unit underneath a cooktop, please also
observe the installation instructions for the cooktop as well as the building-in
height required for the cooktop.

The HAL 5900 trim, available as an optional accessory, is only required when
building the oven into a base unit.

Summary of Contents for HAL 5900

Page 1: ...l or base unit When building the oven into a base unit underneath a cooktop please also observe the installation instructions for the cooktop as well as the building in height required for the cooktop The HAL 5900 trim available as an optional accessory is only required when building the oven into a base unit ...

Page 2: ...11194540 03 Installation INSTALLATION Tall unit side view ...

Page 3: ...11194540 03 Installation INSTALLATION Base unit side view The HAL 5900 trim is available as an optional accessory Fix the HAL trim into the unit cut out under the worktop ...

Page 4: ...11194540 03 Installation INSTALLATION Connections and ventilation a Front view b Mains connection cable length 2 000 mm c No connections permitted in this area d Ventilation cut out min 150 cm ...

Page 5: ...unit Connect the mains cable from the oven to the electricity supply Do not carry the oven by the door handle The door can be damaged Use the handle cut outs on the side of the housing to lift the appliance Remove the door see Cleaning and care Removing the door and the accessories before installing the appliance This makes the oven lighter when you push it into the housing unit and you do not run...

Page 6: ...n additional means of disconnection must be provided for all poles The means of disconnection must be incorporated in the fixed wiring in accordance with the wiring rules When switched off there must be an all pole contact gap of 3 mm in the isolator switch including switch fuses and relays Connection data AC 230V 50 Hz The voltage and rated load are given on the data plate situated at the front o...

Page 7: ... cause irritating voltage fluctuations in single phase connection If the network impedance at the point of coupling to the public supply network is higher than 0 42 Ω additional measures may be required to avoid these irritations If necessary information about the impedance can be inquired at the local distribution network operator ...