background image

Operating and installation instructions

Cooker hoods
DA 230-2, DA 230-2 EXT

It is

essential

to read these

operating instructions before
installing or using the machine
to avoid the risk of accidents
or damage to the machine.

Gi

05 814 920

M.-Nr.

Summary of Contents for DA 230-2

Page 1: ...lation instructions Cooker hoods DA 230 2 DA 230 2 EXT It is essential to read these operating instructions before installing or using the machine to avoid the risk of accidents or damage to the machine Gi 05 814 920 M Nr ...

Page 2: ...f 12 Switching the lighting on 12 To dim the lighting 12 To switch the lighting off 12 Filter operating hours counter 13 Reading the filter operating hours counter 13 Altering the filter operating hours counter 14 Cleaning and care Housing 15 Grease filters 16 Changing a halogen lamp 18 After sales service 19 Appliance dimensions 20 Installation 21 Connection for air extraction 25 Condensate trap ...

Page 3: ...r of suffocation Rather than just throwing these materi als away please ensure that they are recycled Disposal of your old appliance Old appliances may contain materials which can be reclaimed or recycled Please contact your dealer your local waste collection centre or scrap mer chant about potential recycling schemes Ensure that the appliance presents no danger to children while being stored for ...

Page 4: ...electricity supply otherwise the appliance could be damaged Consult a qualified electrician if in doubt The electrical safety of this appli ance can only be guaranteed when continuity is complete between the ap pliance and an effective earthing sys tem which complies with local and na tional regulations It is most important that this basic safety requirement is tested by a qualified electrician Th...

Page 5: ... covered by a pan otherwise flames could be drawn up by the suction of the cooker hood parts of which could then be damaged Always switch the cooker hood on when using the hob otherwise condensation may collect in the hood which could cause corrosion When cooking with oil or fat chip pans and deep fat fryers etc do not leave the pans unattended Never leave an open grill unattended when grilling Ov...

Page 6: ...and they have different minimum safety distances to the cooker hood select the greater dis tance Safety regulations prohibit the fit ting of a cooker hood over solid fuel stoves All ducting pipework and fittings must be of non flammable material These can be obtained from the Miele Spare Parts department or from build ers merchants The appliance must not be con nected to a chimney or vent flue whi...

Page 7: ...other technical measures such as ensuring that the extractor can only be switched on when the heating appli ance is switched off or vice versa N B The overall ventilation condition of the dwelling must be taken into ac count If in any doubt the advice of a competent builder or for gas a Corgi installer must be sought Appliances with external fans For appliances with an external fan motor fitted EX...

Page 8: ...DA 230 2 DA 230 2 EXT Description of the appliance 8 ...

Page 9: ...off automatically af ter either 5 or 15 minutes l Touch control for the grease filters The indicator lamp for the grease filter touch control lights up when the grease filters need to be cleaned The touch control is used to reset the operating hours counter after cleaning the grease filters see Cleaning and Care to show how long the grease filter has been in use see section on Op eration Filter op...

Page 10: ...No ex change of room air and outside air can take place When the cooker hood is switched on the non return flap opens for the cooking vapours to be blown di rectly outside an external fan The EXT models are designed to be connected to an external fan located outside the room The external fan is connected to the cooker hood by means of a control ca ble and is operated by the controls on the cooker ...

Page 11: ...ower setting Depending on the intensity of cooking vapours levels I to III green indica tor lamps are usually sufficient for nor mal cooking Intensive setting When frying or cooking food with a strong aroma you may wish to select the Intensive setting yellow indicator lamp for a short period Run on option If the air still needs to be cleared after cooking the cooker hood can be set to continue run...

Page 12: ...ched on press and hold the hob illumination control in The brightness will gradually dim until you release the control Press the control in again to increase the brightness to the level required and then release it If you keep the control pressed in the brightness will continually go brighter and then dimmer To switch the lighting off Briefly press the hob illumination control to switch the lighti...

Page 13: ...r touch control for about 3 seconds The indicator lamp will go out Reading the filter operating hours counter To check the percentage of time set al ready used Use the On Off touch control to switch the fan on Press the grease filter touch control One or several of the indicator lamps for the touch controls will flash The number of flashing lamps shows the percentage of the operating time which ha...

Page 14: ... more diffi cult Use the On Off touch control to switch the fan off Press the run on option touch control and the grease filter touch control at the same time The indicator lamp for the grease filter touch control and one of the touch control lamps will flash The touch control lamps show the time which has been set 1st lamp from the left 20 hours 2nd lamp from the left 30 hours 3rd lamp from the l...

Page 15: ...ve cleaning agents e g pow der cleaners or cream cleaners abrasive sponges e g pot scourers or sponges which have been previ ously used with abrasive cleaning agents These will damage the surface material Stainless steel Stainless steel surfaces can be cleaned using a proprietary non abrasive clean ing agent designed specifically for use on stainless steel To help prevent re soiling proprietary co...

Page 16: ...e filters by hand with a scrubbing brush in warm water with a little washing up liquid in a dishwasher place the filters with the short side upright in the lower basket ensuring the spray arm is not obstructed Depending on the cleaning agent used cleaning the grease filters in a dishwasher can cause permanent discolouration to the surface of the filters However this will not affect the func tionin...

Page 17: ...not let them drop on to the hob below After replacing the grease filters press the grease filter touch control for approx 3 seconds to re set the operating hours counter The indicator lamp will go out If the grease filters are cleaned be fore the operating hours counter has reached its maximum the grease fil ter touch control should be pressed for approx 6 seconds to reset the counter to zero Clea...

Page 18: ...hanging a lamp as grease particles from your fingers will ad here to the surface and damage it Please follow manufacturer s instruc tions To change the halogen lamp first re move the outer ring a Then detach the circlip b taking care that the glass c does not fall out The halogen lamp d is fitted to a push in connection socket To re place pull out the old lamp and fit a new one Replace the cover c...

Page 19: ... Service Department see back cover for address When contacting the Service Depart ment please quote the model and se rial number of your appliance These are shown on the data plate which is visible when the grease filters are re moved Please note that telephone calls may be monitored and recorded to im prove our service After sales service 19 ...

Page 20: ...he ceiling with ø 8 mm screws b Alternative positions for feeding through the mains cable supply c Cut out for feeding connection cable through to an external fan min 65 x 30 mm d Exhaust connection ø 150 mm Appliance dimensions 20 ...

Page 21: ...s 650 mm above gas cookers and hobs 650 mm above an open grill from our range A distance of 650 mm above electric cookers and hobs may be prefera ble to give more working space See Warning and Safety instructions for further information Installation Mark a line on the ceiling centrally above the hob First make a hole in the ceiling for the exhaust duct at the desired position The exhaust ducting d...

Page 22: ... be used in which case a suitable reducing collar is needed which can be purchased from your supplier or from the Spare Parts Dept see Installation Extraction for further details If the cooker hood is to be connected to an external fan motor create the gap for the connection cable to the fan motor Ensure that the diameter is sufficient to be able to feed through the 6 pole connector Drill four 10 ...

Page 23: ...ws M 6 x 20 into the recessed holes from above Secure the screws from above with some adhesive tape to prevent them from being pushed upwards when the nuts are tightened Screw the ceiling plate to the ceiling with the 8 x 60 mm screws and wash ers For appliances connected to an ex ternal fan model designation EXT Make the connection between the cooker hood and the external fan with the 6 pole conn...

Page 24: ...he cable for electrical con nection as much as possible and se cure inside the cooker hood tower with cable clips Before connecting the appliance read the safety notes in Warning and Safety instructions and in the Electrical connection section Finally push the cover plate upwards until the spring fixing clips click in se curely and the frame lies tightly against the ceiling Before using the applia...

Page 25: ...e cooker hood would increase and extraction would be less efficient Only reduce the diameter of the ducting if absolutely necessary e g where narrower ducting has already been installed Only use wide radius bends Tight bends reduce the air throughput of the cooker hood Only use smooth pipes or flexible hoses made from non flammable ma terials for extraction connection Where ducting is horizontal i...

Page 26: ... be suitably insu lated Condensate trap In addition to insulating the exhaust ducting we recommend that a suitable condensate trap is also installed to col lect and evaporate any condensate which may occur When installing a condensate trap ensure that it is positioned vertically and if possible directly above the ex haust connection Cooker hoods designed for use with an external fan have an integr...

Page 27: ...ease filters have been re moved Ensure that these match the household mains supply For U K Connection should be made by a double pole fused spur connection unit The On Off switch should be easily accessible after the appliance has been built in When switched off there must be an all pole contact gap of 3 mm in the switch including switch fuses and re lays according to EN 60 335 If the socket is no...

Page 28: ...ing to EN 61591 Extraction system ø 150 mm Level I 230 m3 h Level II 350 m3 h Level III 520 m3 h Intensive level 720 m3 h Extraction system ø 125 mm Level I 220 m3 h Level II 330 m3 h Level III 500 m3 h Intensive level 650 m3 h unrestricted 750 m3 h For EXT models the rated load and ex traction power will depend on the type of external fan fitted Technical data 28 ...

Page 29: ...29 ...

Page 30: ...30 ...

Page 31: ...31 ...

Page 32: ...Alteration rights reserved 44 3102 This paper consists of cellulose which has been bleached without the use of chlorine 00 M Nr 05 814 920 V ...

Reviews: