Pump coffee/hot water defective.
•
Coffee/hot water pump – Remove
•
Install a new pump coffee/hot water.
6.3.9
F41
Faulty EEPROM/Wrong data
•
Control electronic EPX – Remove
•
Install a new control electronic.
6.3.10
F42
Main power frequency not registered
•
Verify correct source voltage & frequency.
6.3.11
F47
Faulty interface of control electronic and power electronic.
•
Check the cable between control electronic and power electronic.
•
Replace the connecting cable if necessary.
6.3.12
F73 – Faulty Brew Unit
When the brew unit is activated, if one of the two microswitches does not
switch within approx.10seconds. F73 is registered.
1 Microswitch position controltop (home position)
2 Microswitch position control bottom (compress and drain position)
Figure 6-1:
CVA4070 Faulty Brew Unit